Antibody-free workflows for protein quantification by LC-MS/MS.

نویسندگان

  • Daniel Wilffert
  • Rainer Bischoff
  • Nico C van de Merbel
چکیده

Antibody-free approaches for quantitative LC-MS/MS-based protein bioanalysis are reviewed and critically evaluated, and compared with the more widely used immunoaffinity-based approaches. Antibody-free workflows will be divided into four groups and discussed in the following order: direct analysis of signature peptides after proteolytic digestion; enrichment of target proteins and signature peptides by fractionated protein precipitation; enrichment of target proteins and signature peptides by reversed-phase and ion-exchange solid-phase extraction; and enrichment of target proteins and signature peptides by (antibody-free) affinity-solid-phase extraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis Targeted Quantification, Suspect Screening, and Unknown Compound Identification

This application note presents three complementary LC/Q-TOF workflows designed to provide comprehensive analysis of micropollutants in surface waters: • Targeted quantification • Suspect screening with and without MS/MS spectra • Unknown compound identification The first two workflows rely on the Agilent All Ions MS/MS accurate mass capabilities of the Agilent LC/Q-TOF system, Agilent MassHunte...

متن کامل

DeepIso: A Deep Learning Model for Peptide Feature Detection

Liquid chromatography with tandem mass spectrometry (LC-MS/MS) based proteomics is a well-established research field with major applications such as identification of disease biomarkers, drug discovery, drug design and development. In proteomics, protein identification and quantification is a fundamental task, which is done by first enzymatically digesting it into peptides, and then analyzing p...

متن کامل

Automation of Sample Preparation for Accurate and Scalable Quantification and Characterization of Biotherapeutic Proteins Using the Agilent AssayMAP Bravo Platform

The Agilent AssayMAP Bravo platform automates a wide variety of LC/MS sample prep workflows on a single instrument that is easy to use, gives highly reproducible results, reduces hands-on time, and can simultaneously process 8–96 samples. We report results from two workflows that are routinely used to quantify and characterize biotherapeutic proteins. Peptide quantification was performed using ...

متن کامل

PWA - 138 Statistical Significance in LC-MS based Label-free Protein Quantification Analysis

Label-free MS-based quantification of peptides from LC-MS data is a valuable complement to MS-based quantification technologies such as SILAC, ICPL, or gel based quantification. However, statistically valid labelfree quantification of peptides and proteins from a digest of a proteomics sample in up to hundreds of LC-MS experiments is a challenge, as it requires excellent sensitivity, mass accur...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioanalysis

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2015