Point of care monitoring of oral anticoagulant therapy in children: comparison of CoaguChek Plus and Thrombotest methods with venous international normalised ratio.

نویسندگان

  • Vera Ignjatovic
  • Chris Barnes
  • Fiona Newall
  • Simone Hamilton
  • Janet Burgess
  • Paul Monagle
چکیده

This paper reports the outcome of a research protocol aimed at optimising warfarin monitoring in a tertiary pediatric centre. The Thrombotest INR was the standard monitoring test employed to manage oral anticoagulant therapy in children at the Royal Children's Hospital (RCH), Melbourne. This study compares the results of this standard method to the novel CoaguChek INR monitor and the "gold standard" technique of venous INR sampling. The objectives were to determine 1) if point-of-care techniques of measuring the INR (Thrombotest and CoaguChek) are accurate and reliable compared to INR results obtained from venous sampling, processed in an accredited laboratory, and 2) if INR results generated by POC devices can be safely used to manage oral anticoagulant therapy in children. 18 children (10 females and 8 males) participated in the study. Ages ranged from 9 months to 21 years (Mean 11.9 years; SD 5.03 years). The agreement between CoaguChek and venous INR measurements (r = 0.885) was shown to be higher compared to Thrombotest and venous INR (r = 0.700). Compared to the venous INR, values obtained with Coaguchek and Thrombotest crossed into or out of the therapeutic range in 25% and 36% of cases respectively. In 88% of the CoaguChek cases and 57% Thrombotest cases, the difference from the venous result was less than 0.5. The CoaguChek method of INR monitoring is a more accurate and reliable method compared to Thrombotest, in the pediatric population tested, and can be safely used to manage oral anticoagulant therapy in children.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).

Point-of-care (POC) monitoring of oral anticoagulation has been widely adopted in both paediatric and adult patients. A new POC system, the CoaguChek XS has recently been developed to measure the international normalised ratio (INR) and may offer significant advantages. The CoaguChek XS utilises a new method of electrochemical clot detection based on thrombin generation. This system has not bee...

متن کامل

Self-monitoring of oral anticoagulation therapy in children.

This study aimed to investigate the accuracy of home International Normalized Ratio (INR) self-monitoring in pediatric patients on long-term oral anticoagulation therapy. Statistical and clinical agreement of INR values from capillary whole blood samples measured by 2 different portable prothrombin time monitors (CoaguChek S and XS) and venous blood samples measured by a laboratory coagulation ...

متن کامل

Validation of the CoaguChek XS international normalised ratio point-of-care analyser in patients at Charlotte Maxeke Johannesburg Academic Hospital, South Africa.

BACKGROUND Measurement of the international normalised ratio (INR) is essential in the management of patients on long-term warfarin therapy. The CoaguChek XS portable coagulometer is a point-of-care test for INR measurement. It offers the advantage of improved patient accessibility, particularly in peripheral clinics. OBJECTIVES To evaluate the clinical utility of the CoaguChek XS for monitor...

متن کامل

Comparative study of a portable prothrombin time monitor employing three different systems in oral anticoagulant units.

The aim of this study was to evaluate the accuracy of the portable coagulometer CoaguChek (Roche Diagnostics) as a prothrombin time (PT) monitor, and to correlate capillary blood results with those of three different routine methods used for monitoring oral anticoagulant therapy (OAT): capillary, plasma and whole blood samples. Three hospitals participated in the study with a total of 235 patie...

متن کامل

Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.

Point-of-care INR (POC INR) meters can provide a safe and effective method for monitoring oral vitamin K antagonists (VKAs) in children. Stollery Children's Hospital has a large POC INR meter loan program for children requiring oral VKAs. Our protocol requires that POC INR results be compared to the standard laboratory INR for each child on several consecutive tests to ensure accuracy of CoaguC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thrombosis and haemostasis

دوره 92 4  شماره 

صفحات  -

تاریخ انتشار 2004