Quantification of metals released by metallothionein adsorbates at mercury film electrodes by electrochemical ICP-atomic emission spectrometry
نویسندگان
چکیده
Electrochemistry combined on-line with inductively coupled plasma-atomic emission spectrometry (EC/ICP-AES) was used to study the electrode reactions of rabbit liver metallothionein (MT) adsorbates at thin mercury films (TMFs). Three major oxidation peaks, with peak potentials at −1.20, −0.75 and −0.32 V, were observed. Through the correlation of the DPV characteristics to the elution of the Zn and Cd ions monitored by time-resolved ICP-AES responses, the peak at −1.20 V was assigned to the anodic stripping of Zn(Hg). For the first time, both Zn and Cd were found to be associated with the initial oxidation at −0.75 V by EC/ICP-AES. In the subsequent voltammetric scans, the peak at −0.75 V decreased but remained steady and did not result in the elution of additional metals. The initial decrease in current is suggested to originate from the anodic stripping of the Cd(Hg) amalgam and the Zn–Cd intermetallic compound in the TMF. The anodic peak remaining at −0.75 V was attributed to the formation of the cystine analog from the electrodimerization of the uncomplexed cysteine residues in MT molecules. The quantities of Cd and Zn under the oxidation peaks were measured by EC/ICP-AES. Our work demonstrates that EC/ICP-AES is a viable technique for elucidating relatively complicated electrode reactions that involve metal release and transfer. © 2001 Published by Elsevier Science B.V.
منابع مشابه
Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell
Adsorptions of metallothioneins (MTs) onto thin mercury films (TMFs) at potentials more negative or positive than the point of zero charge (pzc) of mercury were quantified for the first time, using a novel electrochemical quartz crystal microbalance (EQCM) flow cell in conjunction with a simple flow-injection system (FI-EQCM). The EQCM flow cell has a low internal volume (ca. 50 l) designed for...
متن کاملNafion-coated bismuth film and nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry.
Nafion-coated bismuth film electrodes (NCBFEs) and Nafion-coated mercury film electrodes (NCMFEs) were used to electrochemically preconcentrate metal analytes for subsequent analysis by inductively coupled plasma-mass spectrometry (ICP-MS). Either type of electrodes is part of a thin-layer electrochemical flow cell that is positioned upstream of a microconcentric nebulizer for the ICP-MS. Perfo...
متن کاملElectrochemistry combined on-line with atomic mass spectrometry and related techniques for trace-metal analysis and electrode-reaction studies
Electrochemistry (EC) combined on-line with atomic mass spectrometry (MS) and related techniques (e.g., inductively coupled plasma atomic emission spectrometry, ICP–AES) affords an avenue for analysis of metals present at ultratrace levels and the effective elimination of matrix effects detrimental to atomic MS and spectrometric techniques. In addition, electrode reactions involving inorganic s...
متن کاملSimultaneous Automatic Electrochemical Detection of Zinc, Cadmium, Copper and Lead Ions in Environmental Samples Using a Thin-Film Mercury Electrode and an Artificial Neural Network
In this study a device for automatic electrochemical analysis was designed. A three electrodes detection system was attached to a positioning device, which enabled us to move the electrode system from one well to another of a microtitre plate. Disposable carbon tip electrodes were used for Cd(II), Cu(II) and Pb(II) ion quantification, while Zn(II) did not give signal in this electrode configura...
متن کاملA molecular-gap device for specific determination of mercury ions
Specific determination/monitoring of trace mercury ions (Hg(2+)) in environmental water is of significant importance for drinking safety. Complementarily to conventional inductively coupled plasma mass spectrometry and atomic emission/absorption spectroscopy, several methods, i.e., electrochemical, fluorescent, colorimetric, and surface enhanced Raman scattering approaches, have been developed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001