Prognostic value of microvolt T-wave alternans in a real-world ICD population. Twente ICD Cohort Studie (TICS)
نویسندگان
چکیده
INTRODUCTION Survival benefit from ICD implantation is relatively low in primary prevention patients. Better patient selection is important to maintain maximum survival benefit while reducing the number of unnecessary implants. Microvolt T-wave alternans (MTWA) is a promising risk marker. In this study, we aimed to evaluate the predictive value of MTWA in ICD patients. METHODS AND RESULTS This study was a substudy of the Twente ICD Cohort Study (TICS). Patients with ischaemic or non-ischaemic left ventricular dysfunction who received an ICD following current ESC guidelines were eligible for inclusion. Exercise-MTWA was performed and classified as non-negative or negative. The primary endpoint was the composite of mortality and appropriate shock therapy. Analysis was performed in 134 patients (81 % male, mean age 62 years, mean ejection fraction 26.5 %). MTWA was non-negative in 64 %. There was no relation between non-negative MTWA testing and mortality and/or appropriate shock therapy (all p-values >0.15). Due to clinical conditions, 24 % were ineligible for testing. These patients experienced the highest risk for mortality (p < 0.01). CONCLUSION Non-negative MTWA testing did not predict mortality and/or appropriate shock therapy. Furthermore, MTWA testing is not feasible in a large percentage of patients. These ineligible patients experience the highest risk for mortality.
منابع مشابه
Current Developments in Microvolt T-wave Alternans
Microvolt T-wave alternans (MTWA), the beat-to-beat fluctuation in T wave amplitude and morphology, is closely linked to vulnerability to ventricular arrhythmias in various experimental and clinical conditions. Clinically, MTWA is most commonly measured using the spectral method, although non-spectral methods for its assessment from ambulatory electrocardiographical recordings also have been de...
متن کاملMicrovolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy: a solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II conundrum.
BACKGROUND In 2003, the Centers for Medicaid and Medicare Services recommended QRS duration as a means to identify MADIT II-like patients suitable for implanted cardiac defibrillator (ICD) therapy. We compared the ability of microvolt T-wave alternans and QRS duration to identify groups at high and low risk of dying among heart failure patients who met MADIT II criteria for ICD prophylaxis. M...
متن کاملSudden cardiac death risk stratification in dilated cardiomyopathy: climbing the pyramid of knowledge.
N onischemic dilated cardiomyopathy (NIDCM) is the second leading cause of sudden cardiac death (SCD) in the United States. As with coronary artery disease, large-scale clinical trials evaluating implantable cardioverter defibrillator (ICD) therapy based on noninvasive risk markers have focused largely on left ventricular ejection fraction (LVEF). These studies demonstrate that ICD use in selec...
متن کاملProspective Use of Microvolt T-Wave Alternans Testing to Guide Primary Prevention Implantable Cardioverter Defibrillator Therapy.
BACKGROUND We hypothesized that a negative microvolt T-wave alternans (MTWA) test would identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillator (ICD) therapy in a prospective cohort. METHODSANDRESULTS Data were pooled from 8 centers where MTWA testing was performed specifically for the purpose of guiding primary prevention ICD implantation. Cohorts...
متن کاملMicrovolt T-wave alternans and other noninvasive predictors of serious arrhythmic events in patients with an implanted cardioverter-defibrillator.
BACKGROUND Prediction of recurrent malignant ventricular tachyarrhythmias after insertion of a implantable cardioverter-defibrillator (ICD) is challenging. Microvolt T-wave alternans (MTWA) seems to be a promising marker of such events in ICD recipients. AIM To assess prognostic significance of MTWA and other noninvasive parameters in the prediction of major arrhythmic events after ICD implan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 22 شماره
صفحات -