Pressure flow characteristics of the valve in spacer devices 1307 During expiration the flows
نویسندگان
چکیده
During expiration the flows required to close the Volumatic valve were slightly higher than those required to open the valve, but lie still in a range easily achievable by infants. The flows required to close the Nebuhaler valve were significantly higher than those required to close the Volumatic valve. In the vertical position the expiratory flows averaged 73.9 ml/second (range 69-8-81*5 ml/second) for the Nebuhaler and 24-3 ml/second (range 11-7-31-2 ml/second) for the Volumatic. These flows required for valve closure in Nebuhaler may not be achievable by infants. The reported values for peak tidal expiratory flow in normal infants (5 to 11 months of age) are 70 ml/second.5 During most of expiration the flow is likely to be considerably less, especially in infants with obstructive airway diseases. Infants with expiratory flow limitation during tidal breathing can not increase expiratory flows without increasing lung volume. Failure to close the spacer valve exposes the infant to the risk of rebreathing. The intradevice and interdevice coefficients of variation for both types of spacer devices are acceptable. The higher coefficients of variation found during expiration in the Volumatic spacer device than found for Nebuhaler are interesting but of no clinical importance. Thus the intradevice or interdevice variability is not an additional factor to be considered when using airspacers in infancy. Although up to 100 activations of a metered dose inhaler did not result in an increase in the pressure or flow required to open the spacer valve, prolonged use without adequate cleaning could result in the valve becoming 'sticky', thus requiring greater pressures and flows to operate the valve. Furthermore, the simulated inspiration and expiration in the present study were performed using room air. It is possible that humid expired air could cause the valve to become 'sticky'. In conclusion, our results show that the flows required to open the valves in the Volumatic and Nebuhaler spacer devices are within the range of reported values that can be achieved even by flow obstructed infants. Flows required to close the valve, however, may not lie within reported physiological limits for normal tidal breathing of even healthy infants. Further studies, with particular reference to the flows generated during tidal breathing, and the orientation of the device, are needed to evaluate the possible role of aerosol holding chambers in the treatment of wheezy infants.
منابع مشابه
Pressure flow characteristics of the valve in spacer devices.
The valve system in the mouth piece of two spacer devices was analysed. Pressures required to open and close the non-rebreathing valve were very low (less than 0.1 kPa). Inspiratory flow requirements were within physiological limits for infants' normal tidal breathing. Expiratory flow requirements varied significantly, and the flow required to prevent rebreathing from the chamber may exceed the...
متن کاملSimulation and investigation of the effect of oil flow rate, electric signal of flow control valve and controller on the performance of a wet clutch
The using of wet clutches and hydraulic control devices causes a smoothly torque transfer. In this study, a wet clutch was simulated in Simulink MATLAB software. Firstly the mechanical section of the clutch was modeled and then the hydraulic section was simulated with the addition of electric flow control valve and inlet and outlet of oil flow. Finally, the effects of oil flow rate, electric s...
متن کاملInvestigation of the Flow and Cavitation in a Butterfly Valve
Since knowledge on hydrodynamic torque of a butterfly valve is very important for butterfly valve design, its hydrodynamic torque is investigated in this paper. In reality, the investigation of the loss coefficient and torque from some experiments will take a long time and a lot of money. This paper presents a statistical study of the flow past the butterfly valve in a static analysis using com...
متن کاملControl of Nozzle Flow Using Microjets at Supersonic Mach Regime
This article reports the active control of base flows using the experimental procedure. Active control of base pressure helps in reducing the base drag in aerodynamic devices having suddenly expanded flows. Active control in the form of microjets having 0.5 mm radius placed at forty-five degrees apart is employed to control the base pressure. The Mach numbers of the present analysis are 1.7, 2....
متن کاملThe use of wavelet-artificial neural network and adaptive neuro-fuzzy inference system models to predict monthly precipitation
In water supply systems, One of the most important components as safety unit and the current controller (Switching flow and regulate the amount of flow) used in the arrangement of lines of water. In this study, according to multiple ponds in Tanguiyeh dam water pipeline to industrial and mining company Gol Gohar Sirjan Butterfly valve used in these ponds using Fluent software simulation has bee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006