Effects of varying electrode configuration with catheter-mediated defibrillator pulses at the coronary sinus orifice in dogs.
نویسندگان
چکیده
We compared two methods of delivering single damped sine-wave defibrillator pulses to the coronary sinus orifice in 20 dogs. Ten dogs had "unipolar" (coronary sinus to precordial disc) and 10 had "bipolar" (coronary sinus proximal to coronary sinus distal electrode) discharges. Delivered voltage, current, and energy were recorded during each pulse. Electrophysiologic testing was done before and 4 weeks after the procedure. Histologic examination of the atrioventricular groove was done at 1 mm serial sections. For the unipolar configuration a 200 J defibrillator pulse resulted in a peak voltage of 3370 +/- 125 V, a peak current of 21 +/- 4 A, and a delivered energy of 253 +/- 29 J as compared with 3010 +/- 99 V, 70 +/- 4 A, and 144 +/- 18 J, respectively, for the bipolar configuration (p less than .001). Three dogs (two with bipolar, one with unipolar pulses) had gross coronary sinus rupture and died from acute pericardial tamponade. In addition, irrespective of electrode configuration, all dogs showed microscopic rupture of the coronary sinus internal elastic membrane. Transmural atrial scarring occurred in all 10 dogs that received a unipolar pulse but in only two dogs that received a bipolar pulse (p = .0004). Unlike the atrium, injury to the left ventricle was limited in both groups. Similarly, injury to the periannular myocardium was inconsistent and not transmural in either group. No significant electrophysiologic changes were observed. With the present technique, unipolar rather than bipolar catheter-mediated defibrillator pulses result in transmural atrial injury that might prevent accessory pathway conduction. Regardless of electrode configuration, high-energy defibrillator pulses consistently cause some degree of coronary sinus rupture, most likely related to a barotraumatic mechanism.
منابع مشابه
ARfHYlHIA Effects of varying electrode configuration with catheter - mediated defibrillator pulses at the coronary sinus orifice in dogs
We compared two methods of delivering single damped sine-wave defibrillator pulses to the coronary sinus orifice in 20 dogs. Ten dogs had "unipolar" (coronary sinus to precordial disc) and 10 had "bipolar" (coronary sinus proximal to coronary sinus distal electrode) discharges. Delivered voltage, current, and energy were recorded during each pulse. Electrophysiologic testing was done before and...
متن کاملCatheter-mediated electrical ablation of the posterior septum via the coronary sinus: electrophysiologic and histologic observations in dogs.
In a series of 12 dogs, the electrophysiologic and histologic effects of a single damped sine-wave shock delivered via standard electrocatheters to the region of the coronary sinus orifice were investigated. Six dogs received 200 J and six received 360 J of stored energy. The shock was delivered to two consecutive proximal poles of a standard quadripolar catheter positioned at the coronary sinu...
متن کاملShort- and long-term effects of transcatheter ablation of the coronary sinus by radiofrequency energy.
Catheter ablation of left-sided atrioventricular accessory pathways through the coronary sinus by direct-current shock may be complicated by rupture and thrombosis of the coronary sinus and injury to the coronary arteries. This study examined short and long-term effects of radiofrequency catheter ablation of the coronary sinus in 20 closed-chest dogs to determine whether this technique is feasi...
متن کاملTransvenous defibrillation in humans via the coronary sinus.
A consistently effective transvenous defibrillation system for use in automatic defibrillators could significantly alter the approach to patients at risk of sudden death. Transvenous defibrillation systems that use a right ventricular (RV) electrode only or an RV electrode in combination with a chest patch are relatively inefficient at applying current to the posterolateral left ventricle. An R...
متن کاملEffects of myocardial infarction on catheter defibrillation threshold.
Because the automatic implantable defibrillator may be used in patients having ischemic heart disease, it is important to know whether myocardial ischemia changes the threshold for ventricular defibrillation under experimental conditions simulating automatic internal defibrillation. We determined changes in ventricular defibrillation threshold following coronary occlusion, using an electrode ca...