Perturbation and differential Monte Carlo methods for measurement of optical properties in a layered epithelial tissue model.

نویسندگان

  • InSeok Seo
  • Joon S You
  • Carole K Hayakawa
  • Vasan Venugopalan
چکیده

The use of perturbation and differential Monte Carlo (pMC/dMC) methods in conjunction with nonlinear optimization algorithms were proposed recently as a means to solve inverse photon migration problems in regionwise heterogeneous turbid media. We demonstrate the application of pMC/dMC methods for the recovery of optical properties in a two-layer extended epithelial tissue model from experimental measurements of spatially resolved diffuse reflectance. The results demonstrate that pMC/dMC methods provide a rapid and accurate approach to solve two-region inverse photon migration problems in the transport regime, that is, on spatial scales smaller than a transport mean free path and in media where optical scattering need not dominate absorption. The pMC/dMC approach is found to be effective over a broad range of absorption (50 to 400%) and scattering (70 to 130%) perturbations. The recovery of optical properties from spatially resolved diffuse reflectance measurements is examined for different sets of source-detector separation. These results provide some guidance for the design of compact fiber-based probes to determine and isolate optical properties from both epithelial and stromal layers of superficial tissues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sequential estimation of optical properties of a two-layered epithelial tissue model from depth-resolved ultraviolet-visible diffuse reflectance spectra.

A method for estimating the optical properties of two-layered media (such as squamous epithelial tissue) over a range of wavelengths in the ultraviolet-visible spectrum is proposed and tested with Monte Carlo modeling. The method first used a fiber-optic probe with angled illumination and the collection fibers placed at a small separation (<or=300 microm) to restrict the transport of detected l...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

Engineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)

Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...

متن کامل

Monte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique

Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures.  A timely and accurate diagnosis of this disea...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 2007