Development and Validation of an Automated Step Ergometer
نویسندگان
چکیده
Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject's height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60-180 s; 116-160 bpm, respectively). Data was compared with the student's t test and ANOVA; correlations were tested with Pearson's r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach's alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness.
منابع مشابه
Assessing coaching moral competences: Development and initial validation of the Coaching Fairplay Behaviors Inventory
The purpose of the present investigation was to develop and initial validation of a measure for assessing the athletes perceptions of coaches’ behaviors that promote fairplay behaviors. A three-step procedure was undertaken to develop the questionnaire. In the initial step, the literature review provided theoretical and empirical perspectives on how youth sport coaches can influence athletes’ f...
متن کاملDevelopment and Validation of A Decision-Making Donor Conception Questionnaire in Iranian Infertile Couples
Objective The present study was conducted to develop a decision-making questionnaire for selecting donor conception and assess its psychometric properties in Iranian infertile couples. MaterialsAndMethods This scale development study was conducted based on De Vellis’ method (2012) in four steps at Milad Infertility Clinic in Mashhad, Iran. The dimensions of the concept of decision-making were d...
متن کاملAssessing Language Learners’ Knowledge of Speech Acts: A Test Validation Study
Veryfew attempts have been made in the past to develop instruments to measure pragmatic knowledge of second language (L2) learners. The absence of such instruments in the literature of English language teaching (ELT) underscores the need for the researchers to develop new tests that are specifically designed to assess this crucial but less explored aspect of language learners’ (LLs) knowledge. ...
متن کاملDesigning and Validation of One-Step T-ARMS-PCR for Genotyping the eNOS rs1799983 SNP
Background: The transversion of G to T (G894T) in human endothelial nitric oxide synthase (eNOS) gene has profound effects such as male infertility, recurrent miscarriage, multiple sclerosis and cardiovascular diseases.Objectives: Development of a new Multiplex Tetra-Primer Amplifi cation Refractory Mutation System - Polymerase Chain Reaction (T-ARMS-PCR) for detection of...
متن کاملDevelopment and Validation of Macroergonomic Factors Based on the Holden and Karsh Model: A Case Study in Automotive Industry
Introduction: Complex sociotechnical systems, such as automotive industry, require a proper macro-ergonomic approach to design and implement the work system at micro-ergonomic level. The purpose of this study was to develop and validate effective macroeconomic factors to improve productivity, health and safety of employees in the automotive industry based on Holden & Karsh model. Material and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 43 شماره
صفحات -
تاریخ انتشار 2014