Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis.

نویسندگان

  • Nicola Tessitore
  • Valeria Bedogna
  • Linda Gammaro
  • Giovanni Lipari
  • Albino Poli
  • Elda Baggio
  • Maria Firpo
  • Giovanni Morana
  • Giancarlo Mansueto
  • Giuseppe Maschio
چکیده

BACKGROUND Vascular access surveillance by ultrasound dilution blood flow rate (Qa) measurement is widely recommended; however, optimal criteria for detecting stenosis and predicting thrombosis in arteriovenous fistulae (AVFs) are still not clearly defined. METHODS In a blinded trial, we evaluated the accuracy of single Qa measurement, Qa adjusted for mean arterial pressure (Qa/MAP), and decrease in Qa over time (dQa) in detecting stenosis and predicting thrombosis in an unselected population of 120 hemodialysis subjects with native forearm AVFs (91 AVFs, located at the wrist; 29 AVFs, located at the midforearm). All AVFs underwent fistulography, which identified greater than 50% stenosis in 54 cases. RESULTS Receiver operating characteristic curve analysis showed that dQa, Qa, and Qa/MAP have a high stenosis discriminative ability with similar areas under the curve (AUCs), ie, 0.961 +/- 0.025, 0.946 +/- 0.021, and 0.912 +/- 0.032, respectively. In the population as a whole, optimal thresholds for stenosis were Qa less than 750 mL/min alone and in combination with dQa greater than 25% (efficiency, 90%); however, the best threshold depended on anastomotic site; it was Qa less than 750 mL/min for an AVF at the wrist and Qa less than 1,000 mL/min for an AVF in the midforearm. Qa was the best predictor of incipient thrombosis (AUC, 0.981 +/- 0.013) with an optimal threshold at less than 300 mL/min (efficiency, 94%). Pooled intra-assay and interassay variation coefficients were 8.2% for MAP, 7.9% for Qa, and 11.2% for Qa/MAP. CONCLUSION Our study shows that ultrasound dilution Qa measurement is a reproducible and highly accurate tool for detecting stenosis and predicting thrombosis in forearm AVFs. Neither Qa/MAP nor dQa improve the diagnostic performance of Qa alone, although its combination with dQa increases the test's sensitivity for stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arteriovenous access monitoring with ultrasound dilution in a pediatric hemodialysis unit.

BACKGROUND Permanent arteriovenous (AV) access is the preferred access for dialysis delivery in children and adolescents requiring chronic hemodialysis (HD). Ultrasound dilution (UD) monitoring of AV access flow is widely used in adult HD units for the early detection of stenosis but experience in pediatrics is limited. METHODS We monitored all maintenance HD patients with AV access using a n...

متن کامل

Determining when to measure vascular access flow …that may not be enough

Vascular access in hemodialysis patients is crucial. Vascular access monitoring to ensure access patency is important for patient survival, quality of life, and blood vessel care. The ultrasound dilution method for measuring access flow is a screening tool to assess access dysfunction. Park et al. [1] performed a single-center prospective study of the variation in access flow during hemodialysi...

متن کامل

Bedside screening for fistula stenosis should be tailored to the site of the arteriovenous anastomosis.

BACKGROUND AND OBJECTIVES Given different sites of stenosis and access blood flow rates (Qa), the criteria for diagnosing fistula stenosis might vary according to anastomotic site. To test this, we analyzed the database of a prospective blinded study seeking an optimal bedside screening program for fistula stenosis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Several methods used during dia...

متن کامل

Percutaneous transluminal angioplasty in the treatment of stenosis of arteriovenous fistulae for hemodialysis

BACKGROUND Thrombosis following stenosis of arteriovenous fistulae resulting in the loss of vascular access for hemodialysis is an important complication in patients with chronic renal failure. Percutaneous transluminal angioplasty is being used more frequently in the treatment of stenosis aiming at increasing the patency of arteriovenous fistulae. OBJECTIVE To evaluate the primary patency of...

متن کامل

Most Important Chronic Complications of Arteriovenous Fistulas for Hemodialysis

The aim of this review was to highlight the most important complications of arteriovenous fistulas (AVFs) for hemodialysis (HD). The quality of vascular access for HD should be suitable for repeated puncture and allow a high blood flow rate for high-efficiency dialysis with minimal complications. The dialysis staff must be well versed in manipulation of the AVF, and there should be a minimal ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of kidney diseases : the official journal of the National Kidney Foundation

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2003