Predictors of stethoscope contamination following a standardized physical exam

نویسندگان

  • A Schneider
  • C Tschopp
  • Y Longtin
  • G Renzi
  • A Gayet-Ageron
  • J Schrenzel
  • D Pittet
چکیده

Methods Following a standardized physical exam using sterile gloves and a sterile stethoscope, bacterial contamination of the following regions were assessed using contact plates: stethoscope diaphragm, stethoscope tube, fingertips, thenar region, hypothenar region and back of physician’s dominant hand. Total aerobic colony count (ACC) were determined on digital photographs using a counting tool.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are Simulation Stethoscopes a Useful Adjunct for Emergency Residents' Training on High-fidelity Mannequins?

INTRODUCTION Emergency medicine residents use simulation training for many reasons, such as gaining experience with critically ill patients and becoming familiar with disease processes. Residents frequently criticize simulation training using current high-fidelity mannequins due to the poor quality of physical exam findings present, such as auscultatory findings, as it may lead them down an alt...

متن کامل

Contamination of stethoscopes and physicians' hands after a physical examination.

OBJECTIVES To compare the contamination level of physicians' hands and stethoscopes and to explore the risk of cross-transmission of microorganisms through the use of stethoscopes. PATIENTS AND METHODS We conducted a structured prospective study between January 1, 2009, and May 31, 2009, involving 83 inpatients at a Swiss university teaching hospital. After a standardized physical examination...

متن کامل

Predictors of stethoscope disinfection among pediatric health care providers.

BACKGROUND Stethoscopes are contaminated with bacteria, but predictors of stethoscope disinfection frequency are unknown. We sought to describe health care provider stethoscope disinfection attitudes and practices and determine predictors of frequent disinfection. METHODS We used an anonymous online survey of nurses, nurse practitioners, and physicians at a pediatric hospital. We assessed fre...

متن کامل

Contamination Level of Stethoscopes Used By Physicians and Physician Assistants

The Journal of Physician Assistant Education | 2007 Vol 18 No 2 INTRODUCTION The stethoscope is a popular instrument used by health care providers to evaluate the lung, heart, and abdominal sounds of their patients. Although clinicians are instructed about microbiology and the importance of maintaining clean medical instruments, the stethoscope may not be thought of as a potential source of nos...

متن کامل

The stethoscope as a potential source of transmission of bacteria.

To the Editor: Contamination of stethoscopes by skin flora has been described previously. 1 The predominant organisms recovered from stethoscope diaphragms were Staphylococcus epider-midis and Staphylococcus aureus. Previous studies documented the status of contamination of the stethoscope diaphragm with microorganisms only once, and no repeat sampling was performed. 1 The dynamic of contaminat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011