Entrapment of hydrophilic coated coronary guidewire tips: which form of management is best?
نویسندگان
چکیده
Fracture, detachment and entrapment of coronary guidewires is seen infrequently. Different treatment strategies have been performed for such cases in medical literature. Here, we present three different cases of hydrophilic coated coronary guidewire non-metallic tip entrapment. Conservative management was preferred as the main strategy, with a practical approach to fix the guidewire remnant to the coronary bed during intervention. All three patients were asymptomatic following the interventions. Besides case presentation and our treatment, we also briefly review the history and management strategies reported and discussed in the medical literature.
منابع مشابه
Troubleshooting for Ureteroscopy Complicated by Unexpected Guidewire Looping and Entrapment
This report presents a bizarre and unusual case of looping and entrapment of a hydrophilic guidewire in the ureter of a 65-year-old woman with a stone in the lower ureter at the time of ureteroscopy and laser lithotripsy. We describe endourology maneuvers to remove the retained guidewire. Looping and entrapment of guidewire is a rare complication that urologists may face when they do not follow...
متن کاملSurgical removal of guidewire entrapped within stent struts during percutaneous coronary angioplasty.
There has been a growing trend toward percutaneous coronary angioplasty for complex coronary artery lesions. Stent or guidewire break off or trapping within the coronary artery lumen is a rare complication, but it may have fatal consequences. In such cases, the entrapped device may be removed by either percutaneous route or surgical exploration. Here, we report a patient with guidewire entrapme...
متن کاملImpact of guidewire selection and operator expertise on radiation exposure in transradial angiography
BACKGROUND Several studies have implied that the time of radiation exposure for patients and operators during the transradial approach for coronary angiography (TRA) is associated with the use of different guidewire or catheter and operator's finesse. This study aimed to assess the effects of non-hydrophilic or hydrophilic guidewire and operator expertise on fluoroscopy time and procedure time ...
متن کاملDistal protection devices during percutaneous coronary and carotid interventions
Distal embolization of particulate matter complicates percutaneous coronary and peripheral interventions more often than had been recognized until recently. A number of distal protection devices are under development. The PercuSurge GuardWiretrade mark is a balloon occlusion thrombectomy device approved by the United States Food and Drug Administration for saphenous vein graft intervention. A n...
متن کاملRecanalization of occlusive transjugular intrahepatic portosystemic shunts inaccessible to the standard transvenous approach.
PURPOSE The aim of this study was to evaluate the feasibility and safety of recanalization of occlusive transjugular intrahepatic portosystemic shunts (TIPS) that are inaccessible to the standard transvenous approach in patients with occlusive bare and covered stents. MATERIALS AND METHODS From July 1999 to July 2011, 430 consecutive TIPS were performed at a single institution in patients wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiology journal
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2010