Ambulatory blood pressure monitoring evaluation of a semi-automated device.
نویسندگان
چکیده
The accuracy of a semi-automated ambulatory blood pressure monitoring device (the Instrumedix 'Personal Blood Pressure Transmitter') was assessed in 36 patients undergoing diagnostic cardiac catheterisation. Blood pressure readings measured by the device and by a standard manual sphygmomanometer were compared with simultaneous intra-aortic pressure measured directly via the catheter. No measurement size trends were identified for either of the two comparisons. Compared to direct intra-aortic pressure measurement, the manual sphygmomanometer gave lower systolic (p less than 0.05), and higher diastolic readings (p less than 0.01), while the semi-automated device gave slightly higher readings for both systolic (not significant: p greater than 0.05) and diastolic (p greater than 0.05) pressure. In this assessment the semi-automated device provided at least as accurate a reflection of intra-aortic pressure as did standard manual sphygmomanometry. This device is an accurate tool for the ambulatory assessment of blood pressure where adequacy of treatment or correctness of the diagnosis is in question.
منابع مشابه
The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems.
With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many ...
متن کاملEffects of Ramadan fasting on ambulatory blood pressure in hypertensive patients
Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...
متن کاملAutomated blood pressure measurement for diagnosing hypertension.
Guidelines for the management of hypertension have started to include home blood pressure (BP) and 24-h ambulatory BP monitoring as preferred methods for diagnosing hypertension. The next step will be to incorporate automated office BP measurement into the algorithm for diagnosing hypertension. Recent studies support this approach with automated office BP readings being closely correlated with ...
متن کاملResistant hypertension: diagnostic strategies and management.
Blood pressure that remains above target levels despite drug therapy is an increasingly common problem. The evaluation of resistant hypertension includes confirming blood pressure measurements with an automated device that works without the clinician present and with 24-hour ambulatory monitoring; assessing for target-organ damage; and determining if kidney disease is present or if the hyperten...
متن کاملComparison of an in-pharmacy automated blood pressure kiosk to daytime ambulatory blood pressure in hypertensive subjects.
The objective of this study was to compare serial readings from an in-pharmacy automated blood pressure (BP) kiosk to mean daytime ambulatory BP. A total of 100 community-dwelling adults with hypertension underwent (1) three baseline automated office readings; (2) three in-pharmacy readings on each of four visits (12 total) using the PharmaSmart PS-2000 kiosk; and (3) 24-hour ambulatory BP moni...