Zhou, Z., & Warr, P. A. (2016). A High Input Impedance Low Noise Integrated Front-End Amplifier for Neural Monitoring. IEEE Transactions on Biomedical Circuits and Systems, 10(6), 1079-1086. DOI: 10.1109/TBCAS.2016.2525810

ثبت نشده
چکیده

Within neural monitoring systems, the front-end amplifier forms the critical element for signal detection and preprocessing, which determines not only the fidelity of the biosignal, but also impacts power consumption and detector size. In this paper, a novel combined feedback loop-controlled approach is proposed to compensate for input leakage currents generated by low noise amplifiers when in integrated circuit form alongside signal leakage into the input bias network. This loop topology ensures the FEA maintains a high input impedance across all manufacturing and operational variations. Measured results from a prototype manufactured on the AMS 0.35μm CMOS technology is provided. This FEA consumes 3.1 μW in 0.042 mm, achieves input impedance of 42 GΩ, and 18.2 nv/√Hz input-referred noise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exploiting Electrocorticographic Spectral Characteristics for Optimized Signal Chain Design: A 1.08 Analog Front End With Reduced ADC Resolution Requirements

Electrocorticography (ECoG) is an important area of research for Brain-Computer Interface (BCI) development. ECoG, along with some other biopotentials, has spectral characteristics that can be exploited for more optimal front-end performance than is achievable with conventional techniques. This paper optimizes noise performance of such a system and discusses an equalization technique that reduc...

متن کامل

An Autonomous Wireless Sensor Node With Asynchronous ECG Monitoring in 0.18 µm CMOS

The design of a 13.56 MHz/402 MHz autonomous wireless sensor node with asynchronous ECG monitoring for near field communication is presented. The sensor node consists of an RF energy harvester (RFEH), a power management unit, an ECG readout, a data encoder and an RF backscattering transmitter. The energy harvester supplies the system with 1.25 V and offers a power conversion efficiency of 19% f...

متن کامل

An 11 mu w, two-electrode transimpedance biosignal amplifier with active current feedback stabilization

A novel two-electrode biosignal amplifier circuit is demonstrated by using a composite transimpedance amplifier input stage with active current feedback. Micropower, low gain-bandwidth product operational amplifiers can be used, leading to the lowest reported overall power consumption in the literature for a design implemented with off-the-shelf commercial integrated circuits (11 μW). Active cu...

متن کامل

Guest Editorial - Selected Papers from the 2013 IEEE International Solid-State Circuits Conference (ISSCC)

T HE IEEE International Solid-State Circuits Conference (ISSCC) is the flagship conference of the IEEE Solid-State Circuits Society and the foremost global forum for presenting advances in solid-state circuits and systems-on-a-chip. From 2010–2012, the IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS has highlighted selected papers from ISSCC on topics related to biological and healthcare a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017