Label-free measurement of microbicidal gel thickness using low-coherence interferometry.

نویسندگان

  • Kelly E Braun
  • Jeffrey D Boyer
  • Marcus H Henderson
  • David F Katz
  • Adam Wax
چکیده

Spectral-domain low-coherence interferometry (LCI) was used to measure the thickness of microbicidal gels applied to a cylindrical calibration test socket. Microbicides are topical formulations containing active ingredients targeted to inhibit specific pathogens that are currently under development for application to the epithelial lining of the lower female reproductive tract to combat sexually transmitted infections such as HIV. Understanding the deployment and drug delivery of these formulations is vital to maximizing their effectiveness. Previously, in vivo measurements of microbicidal formulation thickness were assessed using fluorescence measurements of fluorescein-labeled gels via an optical endoscope-based device. Here we present an LCI-based device that measures the thickness of a formulation without the use of any exogenous agents by analyzing the interference pattern generated between the reflections from the front and back surface of the sample. Results are presented that validate the effectiveness and performance of the LCI measurement in a clinically relevant system as compared to an existing fluorescence-based method. The impact of the new LCI-based design on in vivo measurements is discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and validation of a multiplexed low coherence interferometry instrument for in vivo clinical measurement of microbicide gel thickness distribution

We present a multiplexed, Fourier-domain low coherence interferometry (mLCI) instrument for in vivo measurement of intravaginal microbicide gel coating thickness distribution over the surface of the vaginal epithelium. The mLCI instrument uses multiple delivery fibers to acquire depth resolved reflection profiles across large scanned tissue areas. Here mLCI has been adapted into an endoscopic s...

متن کامل

Measuring Dilution of Microbicide Gels with Optical Imaging

We present a novel approach for measuring topical microbicide gel dilution using optical imaging. The approach compares gel thickness measurements from fluorimetry and multiplexed low coherence interferometry in order to calculate dilution of a gel. As a microbicide gel becomes diluted at fixed thickness, its mLCI thickness measurement remains constant, while the fluorimetry signal decreases in...

متن کامل

Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics.

We propose and demonstrate novel methods that enable simultaneous measurements of the phase index, the group index, and the geometrical thickness of an optically transparent object by combining optical low-coherence interferometer and confocal optics. The low-coherence interferometer gives information relating the group index with the thickness, while the confocal optics allows access to the ph...

متن کامل

Effect of intravitreous anti-vascular endothelial growth factor therapy on choroidal thickness in neovascular age-related macular degeneration using spectral-domain optical coherence tomography.

A critical method of monitoring patients with neovascular age-related macular degeneration (AMD) being treated with anti–vascular endothelial growth factor (anti-VEGF) is optical coherence tomography (OCT), which uses low-coherence interferometry of light to examine the retina in vivo on a micrometer scale. Recent advances in spectral-domain OCT make visualization of the choroid feasible. Using...

متن کامل

Air etalon facilitated simultaneous measurement of group refractive index and thickness using spectral interferometry.

A simple method based on air etalons of a transparent cavity is proposed to simultaneously measure the group refractive index and thickness of a transparent optical plate by spectral domain low coherence interferometry. In this method, only a single beam path is needed in contrast to the two beam paths, the reference and sample arms, of the conventional Michelson interferometer. An empty cavity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2006