Discordant inter-kit results in the radioimmunoassay for choriogonadotropin in serum.

نویسندگان

  • P J Rzasa
  • V J Caride
  • E K Prokop
چکیده

Discordant results for concentrations of choriogonadotropin (HCG) in sera from five of 162 women are reported, as determined with four commercial radioassay kits: Becton-Dickinson, Clinetics, Corning, and Hybritech. Results ranged from 11.2 to 36.7 int. units/L, when assayed with the Becton-Dickinson kit, but HCG was not detectable when assayed with the other kits. None of the patients was pregnant, and none had evidence of persistent trophoblastic or nontrophoblastic disease. Concentrations of lutropin, follitropin, thyrotropin, triglycerides, cholesterol, protein, and albumin were normal. Assay of diluted sera did not parallel the standard curve, and nonspecific binding in the patients' samples was negligible. Some kits for HCG may be influenced by inherent methodological factors or interfering serum constituents, which can lead to spurious results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

An evaluation of 10 kits for determination of human choriogonadotropin in serum.

We compared 10 commercially available radioimmunoassay kits (American Diagnostics, Becton Dickinson, BioGenex, Clinical Assays, Hybritech, Leeco, Mallinckrodt, Microanalytic, Nuclear Medical Systems, and Radioassay Systems) for determination of human choriogonadotropin (hCG), using serum pools, hCG CR119 (NIH), 2nd I.S. (who), and 1st I.R.P. (who). Criteria were ease of performance, total assay...

متن کامل

A thyrotropin radioimmunoassay kit evaluated vs two reference assays.

We evaluated a double-antibody radioimmunoassay kit for thyrotropin that includes calibrators prepared in a matrix of human serum and involves overnight nonequilibrium. Results were compared with those from two reference assays for thyrotropin. The range of within-assay CVs for the kit for thyrotropin values between 0.9 and 2.4 milli-int. units/L was 2.2 to 5.3%, that for between-assay CVs was ...

متن کامل

Determinationof /3-Choriogonadotropin in HumanPlasma:Evaluationand Comparisonof Five “Kit” Methods

We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BlO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable for reliable determination of low concentrations of this analyte, which is of im...

متن کامل

A specific and sensitive radioimmunoassay for human choriogonadotropin.

A specific and sensitive radioimmunoassay for human choriogonadotropin (hCG) has been developed using rabbit antiserum to chemical analogs of beta subunit of human chorionic gonadotropin prepared by controlled reduction and S-alkylation of its disulfide linkages. The assay was highly specific for hCG as the binding of [125I]-hCG to the antibody was not affected by standard human lutropin, by hu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 1984