Detection of strep throat causing bacterium directly from medical swabs by touch spray-mass spectrometry.
نویسندگان
چکیده
Strep throat causing Streptococcus pyogenes was detected in vitro and in simulated clinical samples by performing touch spray ionization-mass spectrometry. MS analysis took only seconds to reveal characteristic bacterial and human lipids. Medical swabs were used as the substrate for ambient ionization. This work constitutes the initial step in developing a non-invasive MS-based test for clinical diagnosis of strep throat. It is limited to the single species, S. pyogenes, which is responsible for the vast majority of cases. The method is complementary to and, with further testing, a potential alternative to current methods of point-of-care detection of S. pyogenes.
منابع مشابه
Novel, rapid optical immunoassay technique for detection of group A streptococci from pharyngeal specimens: comparison with standard culture methods.
A novel immunoassay system based on the changes in the reflection of light, termed an optical immunoassay (OIA), was utilized to directly detect group A streptococcal (GAS) carbohydrate antigen from clinical specimens. In two studies, a total of 1,275 throat swabs were tested for the presence of this antigen with the Strep A OIA rapid detection system and the results were compared with those of...
متن کاملUsefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis
OBJECTIVE A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. HYPOTHESIS The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infect...
متن کاملStreptococcus A in paediatric accident and emergency: are rapid streptococcal tests and clinical examination of any help?
BACKGROUND Rapid streptococcal tests (RSTs) for streptococcal pharyngitis have made diagnosis at once simpler and more complicated. The American Academy of Pediatrics recommends that all RSTs be confirmed by a follow up throat culture unless local validation has proved the RST to be equally sensitive. AIMS To evaluate (a) RST as a single diagnostic tool, compared with RST with or without thro...
متن کاملComparison of LightCycler PCR, rapid antigen immunoassay, and culture for detection of group A streptococci from throat swabs.
We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced mo...
متن کاملComparison of Directigen Group A Strep Test with a traditional culture technique for detection of group A beta-hemolytic streptococci.
The Directigen Group A Strep Test (DGAST), a new rapid method of detecting group A beta-hemolytic streptococci directly from throat swabs, was compared with a traditional culture technique for the detection of group A beta-hemolytic streptococci. Five hundred oropharyngeal swabs from pediatric and adult patients were cultured and then processed by using the DGAST. Of the 144 specimens positive ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 139 19 شماره
صفحات -
تاریخ انتشار 2014