3D PSF Measurement for a Soft X-ray Microscope and Comparison to Theory

نویسنده

  • J. G. McNally
چکیده

The transmission X-ray microscope’s 3D PSF exhibits an axial asymmetry that cannot be explained by an incoherent imaging model for either a lens or zone plate, with or without spherical aberration. OCIS codes: (340.7460) X-ray microscopy; (180.6900) Three-dimensional microscopy; (110.2990) Image Formation Theory

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement-based estimation of global pupil functions in 3D localization microscopy.

We report the use of a phase retrieval procedure based on maximum likelihood estimation (MLE) to produce an improved, experimentally calibrated model of a point spread function (PSF) for use in three-dimensional (3D) localization microscopy experiments. The method estimates a global pupil phase function (which includes both the PSF and system aberrations) over the full axial range from a simple...

متن کامل

Image Quality Enhancement in X-Ray Microscopy

The goal of this work is to develop digital image processing tools for improving the quality of the images provided by the Göttingen transmission X-ray microscope at BESSY [1, 2]. We first present a method for correcting the inhomogeneous illumination. Then, we present results of image restoration techniques applied to X-ray microscopy images of test objects and of biological specimens containi...

متن کامل

Ray-traicing for 3d Microscope Psf Computation Based on the Refractive Index Map

The TDM (Tomographic diffractive microscope) [1] can provide a 3D optical index map of a specimen. To simulate the propagation of a light ray through the specimen, the principle of finite elements can be used for calculation of meridional rays in inhomogeneous media [2]. Actually, the volume is divided into slices, themselves divided into finite elements that have a constant refractive index ac...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Three-Dimensional X-ray Observation of Atmospheric Biological Samples by Linear-Array Scanning-Electron Generation X-ray Microscope System

Recently, we developed a soft X-ray microscope called the scanning-electron generation X-ray microscope (SGXM), which consists of a simple X-ray detection system that detects X-rays emitted from the interaction between a scanning electron beam (EB) and the thin film of the sample mount. We present herein a three-dimensional (3D) X-ray detection system that is based on the SGXM technology and de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016