Transmission of audible praecordial gallop sounds to right supraclavicular fossa.

نویسندگان

  • G J DiDonna
  • R A O'Rourke
  • K L Peterson
  • J S Karliner
چکیده

To evaluate the significance of audible gallop sounds in the right supraclavicular fossa we performed simultaneous external heart sound recordings at 50 and 100 Hz at the left ventricular apex, left sternal border, and right supraclavicular fossa in 50 patients with audible gallop sounds at the left ventricular apex. In each patient heart sounds were recorded with a simultaneous jugular phlebogram, apex cardiogram, and carotid pulse tracing. In 44 patients an apical fourth heart sound coincident with the 'a' wave of the apex cardiogram was recorded, and in 32 (73%) the fourth heart sound was audible and recordable in the right supraclavicular fossa. A left ventricular third heart sound, coincident with the rapid filling wave of the apex tracing, was present in 25 patients but was recorded in the right supraclavicular fossa in only 7 (28%). Intracardiac phonocardiography (high-fidelity catheter) was performed in six patients with left ventricular gallop sounds and in each instance arterial transmission of the third or fourth heart sound, or both, was present. Five additional patients had a prominent jugular venous 'a' wave, but only two had a soft parasternal fourth heart sound. Intracardiac phonocardiography in these five patients failed to reveal transmission of right ventricular gallop sounds to the superior vena cava. We conclude that since left ventricular gallop sounds commonly are transmitted to the right supraclavicular fossa auscultation in this area is often helphful in their detection. In addition, a prominent jugular venous 'a' wave sometimes produces recordable presystolic vibrations that are occasionally audible as well.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental gallop rhythm in sheep with Gousiekte: correlation of changes in amplitude with haemodynamic parameters.

To investigate the correlation of haemodynamic parameters with the intensity of the gallop sound (S3), use was made of right heart catheterization with a Swan-Ganz catheter to measure the pulmonary and right atrial pressures. The cardiac output was determined with the thermodilution method. A radiocardiogram was obtained after a bolus injection of technetium pertechnetate. The cardiopulmonary f...

متن کامل

Investigation of genesis of gallop sounds in dogs by quantitative phonocardiography and digital frequency analysis ANDRE

Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S,. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequenc...

متن کامل

Evaluation of Thyroid Gland Irradiation in Women with Breast Cancer during Radiotherapy with different Radiation Energies at Supraclavicular Region

Introduction: During treatment of breast cancer, Radiotherapy to the Supraclavicular fossa region results in absorption of radiation by the thyroid gland and consequently leads to hypothyroidism in 40% of patients. The aim of this study was to compare thyroid gland radiation absorption during radiotherapy with different anterior-posterior beam radiation of 6-15 and 15-15 MV pho...

متن کامل

Investigation of genesis of gallop sounds in dogs by quantitative phonocardiography and digital frequency analysis.

Several investigators have noted external gallop sounds to be of higher amplitude than their corresponding internal sounds (S3 and S4). In this study we hoped to determine if S3 and S4 are transmitted in the same manner as S1. In 11 closed-chest dogs, external (apical) and left ventricular pressures and sounds were recorded simultaneously with transducers with identical sensitivity and frequenc...

متن کامل

Triple Heart Rhythm.

Triple heart rhythm stands for the cadence produced when three sounds recur in successive cardiac cycles, just as two sounds compose the familiar dual rhythm of cardiac auscultation, and more rarely, four sounds a quadruple rhythm. The conflicting views on the subject have long served to discourage attempts at a clinical perception of the problem. Disagreement is perhaps best illustrated by rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 37 12  شماره 

صفحات  -