Does permanent atrial fibrillation modify response to cardiac resynchronization therapy in heart failure patients?
نویسندگان
چکیده
INTRODUCTION The benefits of cardiac resynchronization therapy (CRT) documented in heart failure (HF) may be influenced by atrial fibrillation (AF). We aimed to compare CRT response in patients in AF and in sinus rhythm (SR). METHODS We prospectively studied 101 HF patients treated by CRT. Rates of clinical, echocardiographic and functional response, baseline NYHA class and variation, left ventricular ejection fraction, volumes and mass, atrial volumes, cardiopulmonary exercise test (CPET) duration (CPET dur), peak oxygen consumption (VO2max) and ventilatory efficiency (VE/VCO2 slope) were compared between AF and SR patients, before and at three and six months after implantation of a CRT device. RESULTS All patients achieved ≥95% biventricular pacing, and 5.7% underwent atrioventricular junction ablation. Patients were divided into AF (n=35) and SR (n=66) groups; AF patients were older, with larger atrial volumes and lower CPET dur and VO2max before CRT. The percentages of clinical and echocardiographic responders were similar in the two groups, but there were more functional responders in the AF group (71% vs. 39% in SR patients; p=0.012). In SR patients, left atrial volume and left ventricular mass were significantly reduced (p=0.015 and p=0.021, respectively), whereas in AF patients, CPET dur (p=0.003) and VO2max (p=0.001; 0.083 age-adjusted) showed larger increases. CONCLUSION Clinical and echocardiographic response rates were similar in SR and AF patients, with a better functional response in AF. Improvement in left ventricular function and volumes occurred in both groups, but left ventricular mass reduction and left atrial reverse remodeling were seen exclusively in SR patients (ClinicalTrials.gov identifier: NCT02413151; FCT code: PTDC/DES/120249/2010).
منابع مشابه
Comparison of the rhythm control treatment strategy versus the rate control strategy in patients with permanent or long-standing persistent atrial fibrillation and heart failure treated with cardiac resynchronization therapy - a pilot study of Cardiac Resynchronization in Atrial Fibrillation Trial (Pilot-CRAfT): study protocol for a randomized controlled trial
BACKGROUND The only subgroups of patients with heart failure and atrial fibrillation in which the efficacy of cardiac resynchronization therapy has been scientifically proven are patients with indications for right ventricular pacing and patients after atrioventricular junction ablation. However it is unlikely that atrioventricular junction ablation would be a standard procedure in the majority...
متن کاملStep-wise Approach to Permanent His Bundle Pacing
There has been a recent upsurge of interest in permanent His bundle pacing, given increased understanding and appreciation of the role dyssynchronous ventricular activation plays in congestive heart failure and atrial fibrillation. Permanent His bundle pacing gives implanters the ability to avoid causing ventricular dyssynchrony in patients dependent on ventricular pacing, and can provide an al...
متن کاملCardiac resynchronization therapy in patients with permanent atrial fibrillation: results from the Resynchronization for Ambulatory Heart Failure Trial (RAFT).
BACKGROUND Cardiac resynchronization (CRT) prolongs survival in patients with systolic heart failure and QRS prolongation. However, most trials excluded patients with permanent atrial fibrillation. METHODS AND RESULTS The Resynchronization for Ambulatory Heart Failure Trial (RAFT) randomized patients to an implantable cardioverter defibrillator (ICD) or ICD+CRT, stratified by the presence of ...
متن کاملCardiac resynchronization therapy: predictive factors of unsuccessful left ventricular lead implant.
AIMS Cardiac resynchronization therapy is an established therapy for advanced heart failure. However, coronary sinus access and pacing is not achieved in about 5-10% of patients. The aim of this study was to identify predictive factors for failure of left ventricular (LV) lead transvenous implant. METHODS AND RESULTS We evaluated 212 consecutive patients who received a cardiac resynchronizati...
متن کاملPacemaker-mediated tachycardia in an unconventional resynchronization device.
A 67-year-old male patient with heart failure and permanent atrial fibrillation underwent atrio-ventricular nodal ablation and a biventricular device implantation. Instead of a standard cardiac resynchronization therapy device, a DDD pacemaker was implanted with the left ventricular lead in the atrial channel. After the implant, a pacemaker-mediated tachycardia caused by T wave oversensing by t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
دوره 36 10 شماره
صفحات -
تاریخ انتشار 2017