Extending the Dynamic Range of Detectors for Average Particle/Droplet Imaging Methods

نویسنده

  • Peter A. M. Kalt
چکیده

Laser-based diagnostic methods are being applied to more and more flows of theoretical and practical interest and are revealing interesting new flow features. Imaging particles or droplets in Nephelometry and Laser Sheet Dropsizing methods requires a tradeoff between maximised signal to noise ratio, without over-saturating the detector. Droplet imaging results in lognormal pdf (probability density function) distribution of pixel intensity. It is possible to fit a lognormal distribution to the histogram of pixels intensities. If pixel intensities are clipped at a saturated value it is possible to estimate a presumed pdf shape without the effects of saturation from the lognormal fit to the unsaturated histogram. Information about presumed shapes of the pixel intensity pdf is used to generate corrections that can be applied to data to account for saturation. The effects of even slight saturation are shown to be a significant source of error on the derived average. It is found that errors on the determined average exceed 5% when the number of saturated samples exceeds 3% of the total. This study also attempts to delineate limits, within which, the detector saturation can be accurately corrected. It is demonstrated that a simple method for reshaping the clipped part of the pixel intensity histogram makes accurate corrections to account for saturated pixels. These outcomes can be used to correct a saturated signal, quantify the effect of saturation on a derived average and offer a method to correct the derived average in the case of slight to moderate saturation of pixels.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

0 M ar 2 00 5 2 D Detectors for Particle Physics and for Imaging Applications ⋆

The demands on detectors for particle detection as well as for medical and astronomical X-ray imaging are continuously pushing the development of novel pixel detectors. The state of the art in pixel detector technology to date are hybrid pixel detectors in which sensor and read-out integrated circuits are processed on different substrates and connected via high density interconnect structures. ...

متن کامل

Review of Recent Progress in the Development of Cerenkov Ring Imaging Detectors*

In the late 1970’s Ypsilantis and Seguinot’l proposed an extension of the classic binary ‘yes/no” Cerenkov counter to a new kind of particle identification system, with large dynamic range, robust performance and the potential to perform in the “heavy traffic” of the multi-particle jet environment. These new detectors were called Ring Imaging Cerenkov (RICH) counters21 or Cerenkov Ring Imaging ...

متن کامل

Negative Selection Based Data Classification with Flexible Boundaries

One of the most important artificial immune algorithms is negative selection algorithm, which is an anomaly detection and pattern recognition technique; however, recent research has shown the successful application of this algorithm in data classification. Most of the negative selection methods consider deterministic boundaries to distinguish between self and non-self-spaces. In this paper, two...

متن کامل

A silicon strip detector system for high resolution particle tracking in turbulence

We describe a high speed imaging system that is used to track tracer particles in highly turbulent flows. The system uses silicon strip detectors designed for high energy physics experiments and is capable of reading two detectors at a frame rate of 70 kHz. Each detector contains 512 strips and measures a one-dimensional projection of the light striking it. The position measurements from this s...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005