Precision measurement of fermionic collisions using an 87Sr optical lattice clock with 1 x 10(-16) inaccuracy.

نویسندگان

  • Matthew D Swallows
  • Gretchen K Campbell
  • Andrew D Ludlow
  • Martin M Boyd
  • Jan W Thomsen
  • Michael J Martin
  • Sebastian Blatt
  • Travis L Nicholson
  • Jun Ye
چکیده

We describe recent progress on the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10(¿16) fractional frequency level. The dominant contributions to the systematic error are from blackbody radiation shifts and collisional shifts. We discuss the blackbody radiation shift and propose measurements and experimental protocols that should reduce its systematic contribution. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms, and experimentally demonstrate how the uncertainty in this density-dependent correction to the clock frequency is reduced.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

87Sr lattice clock with inaccuracy below 10 -15.

Aided by ultrahigh resolution spectroscopy, the overall systematic uncertainty of the 1S0-3P0 clock resonance for lattice-confined 87Sr has been characterized to 9 x 10(-16). This uncertainty is at a level similar to the Cs-fountain primary standard, while the potential stability for the lattice clocks exceeds that of Cs. The absolute frequency of the clock transition has been measured to be 42...

متن کامل

Inelastic collisions and density-dependent excitation suppression in a 87Sr optical lattice clock

We observe two-body loss of P0 87Sr atoms trapped in a one-dimensional optical lattice. We measure loss rate coefficients for atomic samples between 1 and 6 μK that are prepared either in a single nuclear-spin sublevel or with equal populations in two sublevels. The measured temperature and nuclear-spin preparation dependence of rate coefficients agree well with calculations and reveal that rat...

متن کامل

The absolute frequency of the 87Sr optical clock transition

The absolute frequency of the S0–P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6 × 10−16 represents one of the most accurate measurements of an atomic transition frequency to date. After a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice ...

متن کامل

Suppression of collisional shifts in a strongly interacting lattice clock.

Optical lattice clocks with extremely stable frequency are possible when many atoms are interrogated simultaneously, but this precision may come at the cost of systematic inaccuracy resulting from atomic interactions. Density-dependent frequency shifts can occur even in a clock that uses fermionic atoms if they are subject to inhomogeneous optical excitation. However, sufficiently strong intera...

متن کامل

An Optical Lattice Clock with Spin-polarized 87Sr Atoms

We present a new evaluation of an Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0 → 3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 × 10, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of s...