Effects of the salience of pitch and periodicity information on the intelligibility of four-channel vocoded speech: implications for cochlear implants.
نویسندگان
چکیده
Recent simulations of continuous interleaved sampling (CIS) cochlear implant speech processors have used acoustic stimulation that provides only weak cues to pitch, periodicity, and aperiodicity, although these are regarded as important perceptual factors of speech. Four-channel vocoders simulating CIS processors have been constructed, in which the salience of speech-derived periodicity and pitch information was manipulated. The highest salience of pitch and periodicity was provided by an explicit encoding, using a pulse carrier following fundamental frequency for voiced speech, and a noise carrier during voiceless speech. Other processors included noise-excited vocoders with envelope cutoff frequencies of 32 and 400 Hz. The use of a pulse carrier following fundamental frequency gave substantially higher performance in identification of frequency glides than did vocoders using envelope-modulated noise carriers. The perception of consonant voicing information was improved by processors that preserved periodicity, and connected discourse tracking rates were slightly faster with noise carriers modulated by envelopes with a cutoff frequency of 400 Hz compared to 32 Hz. However, consonant and vowel identification, sentence intelligibility, and connected discourse tracking rates were generally similar through all of the processors. For these speech tasks, pitch and periodicity beyond the weak information available from 400 Hz envelope-modulated noise did not contribute substantially to performance.
منابع مشابه
Relationship between Working Memory, Auditory Perception and Speech Intelligibility in Cochlear Implanted Children of Elementary School
Objectives: This study examined the relationship between working and short-term memory performance, and their effects on cochlear implant outcomes (speech perception and speech production) in cochlear implanted children aged 7-13 years. The study also compared the memory performance of cochlear implanted children with their normal hearing peers. Methods: Thirty-one cochlear impl...
متن کاملEffects of envelope filter cutoff frequency on the intelligibility of Mandarin noise-vocoded speech in babble noise: implications for cochlear implants
In cochlear implants, limited spectral and temporal information is provided. Previous studies argued for different effects of temporal information on speech identification in adverse environments. Particularly, it is unclear how speech intelligibility is influenced by the low-pass cutoff frequency of temporal envelope extractors in noise. The current study explored this issue with Mandarin nois...
متن کاملSpeech Intelligibility of Cochlear-Implanted and Normal-Hearing Children
Introduction: Speech intelligibility, the ability to be understood verbally by listeners, is the gold standard for assessing the effectiveness of cochlear implantation. Thus, the goal of this study was to compare the speech intelligibility between normal-hearing and cochlear-implanted children using the Persian intelligibility test. Materials and Methods: Twenty-six cochlear-implanted childre...
متن کاملSpeech intelligibility in cochlear implant simulations: Effects of carrier type, interfering noise, and subject experience.
Channel vocoders using either tone or band-limited noise carriers have been used in experiments to simulate cochlear implant processing in normal-hearing listeners. Previous results from these experiments have suggested that the two vocoder types produce speech of nearly equal intelligibility in quiet conditions. The purpose of this study was to further compare the performance of tone and noise...
متن کاملPredicting the intelligibility of vocoded speech.
OBJECTIVES The purpose of this study is to evaluate the performance of a number of speech intelligibility indices in terms of predicting the intelligibility of vocoded speech. DESIGN Noise-corrupted sentences were vocoded in a total of 80 conditions, involving three different signal-to-noise ratio levels (-5, 0, and 5 dB) and two types of maskers (steady state noise and two-talker). Tone-voco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 108 4 شماره
صفحات -
تاریخ انتشار 2000