Transcatheter closure of atrial septal defect in children up to 10 kg of body weight with Amplatzer device.
نویسندگان
چکیده
BACKGROUND Transcatheter closure of atrial septal defect (ASD) in older children and adults is currently considered the first-choice therapeutic option. This approach remains challenging in younger children. The aim of the study was to evaluate feasibility, safety and midterm efficacy of percutaneous ASD closure in symptomatic infants ≤10 kg body weight in our institution. METHODS There were 28 children up to 10 kg of body weight, who were qualified for transcatheter closure of ASD. All patients but one showed overload of right atrium and right ventricle. Mean weight of patients who underwent transcatheter closure was 9.2 ± 0.88 kg and age 1.59 ± 0.58 years, respectively. Transcatheter closure of ASD was conducted using Amplatzer occluders (ASO). RESULTS The devices were implanted successfully in 26/28 patients (93%). In 2 (7%) children the device repeatedly straddled the septum in relatively big ASD and the procedure was abandoned. Mean ASD diameter in patients, who underwent transcatheter closure, was 9.08 ± 2.9 mm (transthoracic echocardiography) and mean implant size/weight ratio was 1.07 ± 0.31. In the child with right-left shunt through ASD normalization of saturation occurred. Mean fluoroscopy time was 4.16 min. In 3 children minor complications occurred: transient arrhythmias (n = 1), fever after procedure (n = 2). The follow-up time was 6.1 (range 1.2-11) years. At follow-up, clinical condition and/or growth improved in all patients except 4 children with coexisting comorbidity. No arrhythmia nor conduction disturbances were observed during follow-up. CONCLUSIONS In selected patients weighing less or equal to 10 kg, percutaneous closure of ASD is a safe and effective procedure.
منابع مشابه
Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملTranscatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.
AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...
متن کاملAssessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.
OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...
متن کاملTranscatheter closure of atrial septal defects without fluoroscopy: feasibility of a new method.
BACKGROUND In an effort to reduce x-ray exposure, we developed a technique for transcatheter closure of atrial septal defects under echocardiographic guidance without fluoroscopy. To assess the efficiency of this procedure for routine use, we compared our initial results with those for the conventional procedure. METHODS AND RESULTS Twenty-two randomly selected patients (median age 18 years; ...
متن کاملOutcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder
PURPOSE For the successful completion of transcatheter closure of atrial septal defects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the device. The purpose of this study is to evaluate the results of a transcatheter closure of oval shaped atrial septal defect. MATERIALS AND METHODS From November 2009 until November 2011, cardiac computed to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiology journal
دوره 21 3 شماره
صفحات -
تاریخ انتشار 2014