Usefulness of unipolar electrograms to detect isthmus block after radiofrequency ablation of typical atrial flutter.
نویسندگان
چکیده
BACKGROUND RS morphology of the unipolar electrogram is associated with propagation of the wave front through the exploring electrode, whereas positive uniphasic (R) unipolar electrograms are characteristic of the end of activation. METHODS AND RESULTS Unipolar electrograms were recorded in 45 consecutive patients with atrial flutter who were undergoing radiofrequency ablation (RFA). Bidirectional cavotricuspid isthmus (CTI) block was achieved in 44 patients. The unipolar electrogram obtained before RFA at the low anterolateral right atrium during coronary sinus pacing changed from RS, rS, or QS to R or Rs in all patients after clockwise CTI block was obtained. The morphology of unipolar electrograms recorded close to the coronary sinus during pacing from the low anterolateral right atrium changed from RS or rS to R or Rs in all but 4 patients after counterclockwise CTI block. In the patient in whom CTI block was not achieved, the RS morphology of the unipolar electrogram remained unchanged. In 18 patients, the results of the RFA were assessed with only the unipolar electrogram. The unipolar electrogram correctly predicted 100% and 89% of the cases of clockwise and counterclockwise CTI block, respectively. CONCLUSIONS The creation of CTI block is associated with an easily detectable loss of negative components and development of an R or Rs pattern of the unipolar electrogram recorded close to the ablation line while pacing at the opposite side of the CTI.
منابع مشابه
Electrogram polarity and cavotricuspid isthmus block during ablation of typical atrial flutter.
INTRODUCTION The atrial activation sequence around the tricuspid annulus has been used to assess whether complete block has been achieved across the cavotricuspid isthmus during radiofrequency ablation of typical atrial flutter. However, sometimes the atrial activation sequence does not clearly establish the presence or absence of complete block. The purpose of this study was to determine wheth...
متن کاملPartial cavotricuspid isthmus block before ablation in patients with typical atrial flutter.
OBJECTIVES The purpose of this study was to prospectively evaluate preexisting partial isthmus block in the context of an electrophysiologically directed linear ablation strategy for typical atrial flutter (AF). BACKGROUND Double potentials (DPs) separated by an isoelectric interval have been recognized as markers of local block. However, the presence and significance of DPs in the cavotricus...
متن کاملBipolar radiofrequency catheter ablation for refractory perimitral flutter: a case report
BACKGROUND Mitral isthmus is often targeted as a part of stepwise approach during radiofrequency ablation for persistent atrial ablation. Acute success rate in achieving the mitral isthmus block is only modest, late reconduction rate is relatively high and, consequently, incomplete lesion may be proarrhythmic. We describe the first-in-man experience with successful MI ablation by bipolar RF ene...
متن کاملDouble potentials along the ablation line as a guide to radiofrequency ablation of typical atrial flutter.
OBJECTIVES The purpose of this study was to determine the characteristics of double potentials (DPs) that are helpful in guiding ablation within the cavo-tricuspid isthmus. BACKGROUND Double potentials have been considered a reliable criterion of cavo-tricuspid isthmus block in patients undergoing radiofrequency ablation of typical atrial flutter (AFL). However, the minimal degree of separati...
متن کاملIs 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?
BACKGROUND The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available. METHODS AND RESULTS A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 102 25 شماره
صفحات -
تاریخ انتشار 2000