An in vivo comparative evaluation to determine the accuracy of working length between radiographic and electronic apex locators.

نویسندگان

  • S Vijay Singh
  • Vineeta Nikhil
  • Aruna Vijay Singh
  • Suman Yadav
چکیده

BACKGROUND An in vivo comparative evaluation to determine the accuracy of working length between radiographic and electronic apex locators. AIM The study was aimed at evaluating the accuracy of electronic apex locator, to determine the working length of root canal, and to compare it with the radiographic method of working length determination. MATERIALS AND METHODS A total of 20 teeth selected for the study had to go for extraction because of periodontal or orthodontic reasons. Access cavity was prepared and the clinical estimated working length (CEWL) was determined with 10-25 no. K-file. A radiograph was then taken for determining the radiographic estimated working length (REWL). For electronic measurement of root canal, a 10 no. K-file was advanced toward the apex until it reached a 0.5 mm short of apex as shown by the apex locator. After fixing the file with a light cured composite, the tooth was extracted, the tooth surface was then longitudinally grounded using straight fissure diamond bur until the root canal and the tip of the file were visible. The distance of file from the minor constriction was measured with help of stereomicroscope. STATISTICAL ANALYSIS The chi-square test was used for statistical analysis for this study. RESULTS The chi-square test where χ² = 21.034 with P = 0.000 indicated that a significant difference exists among the groups. The electronic method showed highest number of cases with the working length at the minor constrictor. CONCLUSION The electronic method for determining the working length of root canal was found to be more accurate than the radiographic method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

مقایسه دقت دستگاه‌های اپکس یاب الکترونیکی ZX Root،Novapex  در مقایسه با رادیوگرافی در شرایط in vivo

Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study. Materials and...

متن کامل

Evaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study

Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex®6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, singl...

متن کامل

ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)

Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...

متن کامل

The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants

BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Indian journal of dental research : official publication of Indian Society for Dental Research

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 2012