The dark perimetric stimulus.
نویسندگان
چکیده
We determined the disappearance eccentricities of dark and bright stimuli of equal size in the inferonasal central visual field using the oculokinetic perimetry technique at different levels of surrounding illumination. The results suggest that a dark stimulus on a bright background has a smaller 'isoptre' than an equally bright stimulus on a dark background, and that variation of ambient illumination and consequent alteration of background luminance have less effect on the visibility of a dark stimulus than a bright one.
منابع مشابه
Customizing Perimetric Locations Based on En Face Images of Retinal Nerve Fiber Bundles With Glaucomatous Damage
Purpose Prior studies suggested the use of customized perimetric locations in glaucoma; these studies were limited by imaging only the superficial depths of the retinal nerve fiber layer (RNFL) and by prolonged perimetric testing. We aimed to develop a rapid perimetric test guided by high-resolution images of RNFL bundles. Methods We recruited 10 patients with glaucoma, ages 56 to 80 years, m...
متن کاملAngioscotoma detection with fundus-oriented perimetry A study with dark and bright stimuli of different sizes
Fundus-oriented perimetry (FOP) was used to evaluate the effectiveness of different-sized bright and dark stimuli in detecting and quantitatively measuring angioscotoma. The foveolas and optic disks of digitized fundus images were aligned with their psychophysical counterparts to construct individual grids of perimetric stimuli. Each grid included a linear set of test point locations crossing a...
متن کاملResponses of primate retinal ganglion cells to perimetric stimuli.
PURPOSE Perimetry is used clinically to assess glaucomatous ganglion cell loss. It has been proposed that frequency-doubling stimuli are better than the conventional size III perimetric stimulus in preferentially stimulating magnocellular (M) versus parvocellular (P) ganglion cells. However, little is known about how primate ganglion cells respond to perimetric stimuli. The authors recorded con...
متن کاملPerimetric motion thresholds are elevated in glaucoma suspects and glaucoma patients
The purpose of this study was to determine if a clinically feasible perimetric motion test utilizing random-dot kinematograms could identify glaucomatous visual field defects. Using a staircase procedure, an automated perimetric motion test and a larger foveally presented target were given to normal (n = 30), glaucoma suspects (n = 31) and primary open-angle glaucoma patients (n = 19). Motion t...
متن کاملStimulus parameters for goldmann kinetic perimetry in nonorganic visual loss.
OBJECTIVE To investigate the influence of the stimulus parameters on perimetry at various distances and draw conclusions for the clinical exploration of nonorganic visual loss. METHODS Visual field testing using Goldmann kinetic perimetry was performed on 15 healthy volunteers. The I/1e isopter at 33 cm was compared to the I/1e, II/1e and I/2e isopters at 66 cm. The 0/1e isopter at 33 cm was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 76 5 شماره
صفحات -
تاریخ انتشار 1992