Effect of preservation on the elasticity of human aortic valve homografts.

نویسندگان

  • Y L Ng
  • J E Wright
چکیده

The elastic properties of preserved human aortic homografts after different storage times in antibiotic-nutrient medium solution have been measured. There was a definite loss of elasticity within nine months leading to a rapid decrease after a year of preservation. It is likely that satisfactory valve function depends on its elasticity, and these studies indicate that aortic valves which have been exposed to antibiotic media for more than nine months should not be used in valve replacement surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preservation and function of heterologous aortic valves. An experimental study.

Heterologous aortic valves are used in many clinics as replacements for diseased human aortic and mitral valves. These valves possess all the advantages of homologous aortic valves and are more easily available to the surgeon. The heterologous valve also provides a greater choice of valve size than does the homograft; this can be of importance when replacing the mitral valve. Hetero-graft valve...

متن کامل

Aortic valve replacement with homograft and autograft valves. Performance of 615 valves over 15 years.

Homograft valve replacement of the diseased aortic valve with a homologous aortic valve inserted in the sub-coronary position was first performed in July 1962 (Ross 1962). The procedure of transferring the patients autologous pulmonary valve to the aortic position has been used since 1967 (Ross 1967). The long term performance of homograft vaives has not been regarded as satis facrory in some c...

متن کامل

Long-Term Structural Valve Degeneration in Cryopreserved Mitral and Aortic Homograft: Is Pregnancy a Factor?

Objective: This study reports the outcomes of the cryopreserved mitral homograft in 119 patients prospectively followed with clinical, echocardiographic and structural valve deterioration assessments. Methods: 119 patients undergoing mitral and aortic homograft implantation. Patient’s causes of mitral disease were: rheumatic disease (n = 75), endocarditis (n = 37) and others (n = 7). There were...

متن کامل

Pii: S1010-7940(01)00885-5

Objectives: We evaluated the effect of homograft/native aortic root geometric matching and mismatching on valve survival and myocardial remodeling. Methods: Between January 1, 1987 and March 2000, a total of 292 patients, aged 1.5–78 years (mean, 46.2 years), underwent freehand subcoronary aortic valve (AVR; n 1⁄4 207) and root (ARR; n 1⁄4 85) replacement with matched and mismatched cryopreserv...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 1975