Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
نویسندگان
چکیده
This study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The NH3 concentration of both housing systems was also investigated in relation to the pig's growth. The ventilation systems used were; negative pressure type for the enclosed pig house (EPH) and natural airflow for the conventional pig house (CPH). Against a highly fluctuating outdoor temperature, the EPH was able to maintain a stable temperature at 24.8 to 29.1°C during summer and 17.9 to 23.1°C during winter whilst the CPH had a wider temperature variance during summer at 24.7 to 32.3°C. However, the temperature fluctuation of the CPH during winter was almost the same with that of EPH at 14.5 to 18.2°C. The NH3 levels in the CPH ranged from 9.31 to 16.9 mg/L during summer and 5.1 to 19.7 mg/L during winter whilst that of the EPH pig house was 7.9 to 16.1 mg/L and 3.7 to 9.6 mg/L during summer and winter, respectively. These values were less than the critical ammonia level for pigs with the EPH maintaining a lower level than the CPH in both winter and summer. The air velocity at pig nose level in the EPH during summer was 0.23 m/s, enough to provide comfort because of the unique design of the inlet feature. However, no air movement was observed in almost all the lower portions of the CPH during winter because of the absence of an inlet feature. There was a significant improvement in weight gain and feed intake of pigs reared in the EPH compared to the CPH (p<0.05). These findings proved that despite the difference in the housing systems, a stable indoor temperature was necessary to minimize the impact of an avoidable and highly fluctuating outdoor temperature. The EPH consistently maintained an effective indoor airspeed irrespective of season; however the CPH had defective and stagnant air at pig nose level during winter. Characteristics of airflow direction and pattern were consistent relative to housing system during both summer and winter but not of airspeed. The ideal air velocity measurement favored the EPH and therefore can be appropriate for the Korean environment. Further emphasis on its cost effectiveness will be the subject of future investigations.
منابع مشابه
Exploring implications of new EU legislation for animal welfare and of trends in organic farming on ammonia emissions
Animal welfare legislation in the EU, i.e., the EU Directives for the protection of farm animals coming into force by 2013 the latest, and the EU Regulation on organic farming might lead to an increase in ammonia (NH3) emissions. A review of the available, although rather limited, literature reveals that animal-friendly housings systems, in line with welfare legislation, are not ammonia-neutral...
متن کاملInfluence of Temperature, Humidity and Ventilation Rate on the Release of Odour and Ammonia in a Floor Housing System for Laying Hens
The air in floor housing systems for laying hens may be more polluted than in traditional cage systems since gases are emitted from large exposed surfaces of manure and litter. In order to study odour and ammonia concentrations and emissions at different climatic conditions a small scale poultry house (climate chamber) was equipped with a floor housing system were 356 laying hens were kept. Tem...
متن کاملEnvironmental impacts and sustainability of egg production systems.
As part of a systemic assessment toward social sustainability of egg production, we have reviewed current knowledge about the environmental impacts of egg production systems and identified topics requiring further research. Currently, we know that 1) high-rise cage houses generally have poorer air quality and emit more ammonia than manure belt (MB) cage houses; 2) manure removal frequency in MB...
متن کاملTemporal and spatial distributions of aerial contaminants in an enclosed pig building in winter.
Optimal management of indoor air quality in an enclosed swine house, especially in winter, is indispensable for preventing the transmission of infectious respiratory disease to workers and animals. Studies are needed to elucidate the correlation of aerial contaminants and climate factors. It was observed that indoor air contamination in an enclosed pig building was the highest at 2:00--5:00 PM,...
متن کاملExperimental study and application of computational fluid dynamics on the prediction of air velocity and temperature in a ventilated chamber
The shape of the air flow in the interior is heavily influenced by the air distribution system and the way air enters and exits. By numerically simulating flow by computational fluid dynamics, one can determine the flow pattern and temperature distribution and, with the help of the results, provide an optimal design of the air conditioning system. In this study, a chamber was first constructed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 26 شماره
صفحات -
تاریخ انتشار 2013