Establishment of carpal contents/canal ratio by means of magnetic resonance imaging.
نویسندگان
چکیده
Magnetic resonance imaging (MRI) was used to determine cross-sectional areas and volumes of carpal canals and carpal canal contents in five cadaver specimens in an assessment of the reliability of MRI for establishing contents/canal ratios. Volumes of the carpal canals and their contents were accurately calculated from MRI with a previously described correction factor (0.8161) for carpal tunnel volumes and a calculated correction factor (1.078) for carpal tunnel contents volume. There was no significant difference between laboratory-measured or MRI-calculated ratios from either volumes (p = 0.86) or surface areas (p greater than 0.79). Cross-sectional area contents/canal ratios were significantly higher (p = 0.0001) at the level of the distal aspect of the hook of the hamate (0.54) as compared with those at the level of the distal radial styloid (0.42) and proximal metacarpals (0.44). MRI provides an effective and reliable means of determining contents/canal ratios from both cross-sectional area and volume calculations.
منابع مشابه
A New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کاملDesigning and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملIron-gold (Fe2O3@Au) core-shell nano-theranostic for magnetically targeted photothermal therapy under magnetic resonance imaging guidance
Introduction: Photothermal therapy (PTT) is a nanotechnology-assisted cancer hyperthermia approach in which the interaction between laser light and plasmonic nanoparticles generates a localized heating for thermoablation of the tumor. Recent efforts in the area of PTT follow two important aims: (i) exploitation of targeting strategies for preferential accumulation of plasmonic ...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملCarpal Tunnel Syndrome in Association with Klippel-Trénaunay Syndrome: A Case Report
Klippel-Trénaunay syndrome is a rare congenital condition that rarely affects peripheral nerves. Median nerve involvement at carpal tunnel level has only been reported in a few occasions in the medial literature. A 61 years old Caucasian female patient with Klippel-Trénaunay syndrome presented with a 10 months history of paraesthesiae and numbness affecting the median nerve distribution area...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of hand surgery
دوره 17 5 شماره
صفحات -