Effect of Left Atrial Ablation Process and Strategy on Microemboli Formation During Irrigated Radiofrequency Catheter Ablation in an In Vivo Model.

نویسندگان

  • Mitsuru Takami
  • H Immo Lehmann
  • Kay D Parker
  • Kirk M Welker
  • Susan B Johnson
  • Douglas L Packer
چکیده

BACKGROUND Formation of microemboli during catheter ablation has been suggested as a cause for asymptomatic cerebral emboli. However, it is unknown which part of the process and ablation setting/strategy is most strongly related to this occurrence. METHODS AND RESULTS A total of 27 pigs were used. Catheter/sheath manipulations in left atrium were performed in 25 of 27 pigs outfitted with microemboli monitoring systems. Ablations using open-irrigated radiofrequency catheters were performed in 18 of 25 pigs. Two of 27 pigs did not undergo left atrial procedures and were injected with microembolic materials in the carotid artery to serve as positive controls. In total, 334 sheath/catheter manipulations (transseptal puncture, sheath flushing, catheter insertion, pulmonary vein venography, and sheath exchange) and 333 radiofrequency applications (power setting, 30/50 W; point-by-point/drag ablations) were analyzed. High microbubble volume in the extracorporeal circulation loop and a high number of microembolic signals in carotid artery were observed during sheath/catheter manipulations especially in saline/contrast injections at fast speed and ablations with steam pop. Fast sheath flushing produced significantly higher microbubble volume than slow sheath flushing (median, 12 200 versus 121 nL; P<0.0001). A total of 44 of 126 (35%) blood filters in the circulation loop showed microparticles (thrombus/coagulum and tissue). Most of them were seen after radiofrequency application especially in 50-W ablations, drag ablations, and steam pop. Brain magnetic resonance imaging showed positive-embolic lesions in control pigs. CONCLUSIONS Formation of microbubbles was the greatest during fast saline/contrast injections and steam pops, whereas high-power radiofrequency applications, drag ablations, and steam pops produced most of the microparticles.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microembolism and catheter ablation I: a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia.

BACKGROUND Cerebral diffusion-weighted MRI lesions have been observed after catheter ablation of atrial fibrillation. We hypothesized that conditions predisposing to microembolization could be identified using a porcine model of pulmonary vein ablation and an extracorporeal circulation loop. METHODS AND RESULTS Ablations of the pulmonary veins were performed in 18 swine with echo monitoring. ...

متن کامل

Irrigated Versus Dry Radiofrequency Epicardial Ablations in the Treatment of Atrial Fibrillation

Background: Dry radiofrequency (RF) ablation is an established form of surgical treatment of atrial fibrillation and many groups have reported good clinical results . One limiting factor of this type of ablation is that transmural lesions are not consistently obtained . Several reports on percutaneous ablation have shown that catheter irrigation leads to larger volume lesions than nonirrigated ...

متن کامل

Tissue rupture and bubble formation during radiofrequency catheter ablation: "echoes of a pop".

The popping phenomenon during radiofrequency catheter ablation is well known to experienced electrophysiologists. When the electrode-tissue interface temperature increases rapidly above the boiling point, it can vaporize blood, thus causing a mini-explosion and an audible pop. Evaporation may occur intramurally, leading to gas bubble formation within the tissue. With continued energy applicatio...

متن کامل

Pulmonary Embolism as a Complication after radiofrequency catheter ablation Study: A Case Report

Pulmonary thromboembolism (PTE) is a fatal condition that may rarely occur due to complications of coronary catheter insertion. In this case report, a 41-year-old male was presented 48 hours after radiofrequency catheter ablation(RFCA) for the management of Wolf-Parkinson-White syndromewith acute onset of dyspnea, hemoptysis, and chest pain. The physical examination revealed coarse crackles in ...

متن کامل

Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.

BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2016