Quantification of aortic valvular regurgitation in dogs by nuclear imaging.
نویسندگان
چکیده
Radionuclide gated cardiac blood pool (GBP) imaging was used to quantitatively assess the severity of acute aortic valvular regurgitation produced experimentally in 10 anesthetized dogs. Right ventricular (RV) and left ventricular (LV) stroke counts (end-diastolic minus end-systolic counts in RV and LV regions of interest) were used as indices of the stroke volumes of the two ventricles. Regurgitant fraction (RFGBP) was derived by assuming that an excess of LV stroke counts compared to RV stroke counts was due to regurgitant flow: RFGBP = LV stroke counts - RV stroke counts/LV stroke counts X 100. Regurgitant fraction (RFEMF) was also estimated directly from an electromagnetic flowmeter (EMF) on the ascending aorta. Mean RFEMF was 55.8 +/- 17.9% (+/-SD). Close agreement was found between regurgitant fractions measured by GBP and EMF (RFGBP = 1.09, RFEMF - 4.7%, r = 0.88, p less than 0.001, SEE = 9.98%). The severity of regurgitation from blood pool images also correlated closely with aortic pulse pressure (r = 0.89) and the length of the tear in the aortic valve (r = 0.84). These results suggest that blood pool imaging may be sueful for noninvasive quantification of regurgitant flow in patients with valvular insufficiency.
منابع مشابه
Evaluation of diastolic blood flow dynamic of the left ventricle in dogs with mitral valve regurgitation using vector flow mapping
Mitral valve regurgitation (MVR) is a common valvular disease in dogs. Hydrokinetic evaluation of the blood flow within the ventricles has become possible by vector flow mapping (VFM), which shows the blood flow within the ventricles in vector and vortex flows. Blood flow within the left ventricle of MVR dogs was compared at different stages of MVR and to that of normal dogs. 14 normal dogs and...
متن کاملFunctional aspects of cardiovascular nuclear magnetic resonance imaging. Techniques and application.
91. Sechtem U, Pflugfelder PW, Cassidy MM, White RD, CheitlinMD, Schiller NB, Higgins CB. Mitral or aortic regurgitation: quantification of regurgitant volumes with cine MR imaging.Radiology. 1988;167:425-430. 92. Globits S, Mayr H, Frank H, Neuhold A, Glogar D. Quantifica-tion of regurgitant lesions by MRI. Int J Cardiac Imaging. 1991;6:109-116. 93. Wagner S, Auffermann W, ...
متن کاملEuropean Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease).
Valvular regurgitation represents an important cause of cardiovascular morbidity and mortality. Echocardiography has become the primary non-invasive imaging method for the evaluation of valvular regurgitation. The echocardiographic assessment of valvular regurgitation should integrate quantification of the regurgitation, assessment of the valve anatomy, and function as well as the consequences ...
متن کاملEfficient Approaches for Quantification of Aortic Regurgitation Using Proximal Isovelocity Surface Area Process
Aortic Regurgitation is also known as Aortic Insufficiency (AI). It indicates the inability of the aortic valve. During diastole, the aortic valve allows blood flow in the reverse direction from aorta into the left ventricle. Regurgitation is due to incompetence of the aortic valve or any disorder of the valvular apparatus (e.g., leaflets, annulus of the aorta) ensuing in diastolic flow of bloo...
متن کاملQuantification of aortic regurgitation and stroke volume by CMR - variation due to slice plane position. It matters where you measure!
Purpose Aortic regurgitation by CMR has been assessed in various locations, including sinus of valsalva (SOV), sinotubular junction (STJ), and ascending aorta (ASC). Variability in obtained measurements and interchangeability of these locations and methods in patients with varying valvular disease severity is unknown. We sought to determine the most appropriate aortic level for accurate phase c...