The "eyetone" blood glucose reflectance colorimeter evaluated for in vitro and in vivo accuracy and clinical efficacy.
نویسندگان
چکیده
We evaluated the performance of a blood glucose reflectance colorimeter ("Eyetone," Ames Co.) for accuracy and precision with use of "Dextrostix" (Ames Co.) glucose oxidase reagent strips for blood samples with known and unknown concentrations of glucose covering the usual range of neonatal blood glucose (200-800 mg/L). The meter was calibrated and tested by research nurses and one clinical chemist. Five unknowns were tested for accuracy and precision (56-92 determinations per unknown) and compared with Beckman Astra values (plasma and calculated whole blood). Eyetone/Dextrostix values differed (gave lower values) from the calculated whole-blood values only at concentrations less than 300 mg/L. On 258 clinical specimens from newborn infants, Eyetone/Dextrostix values were not different from calculated whole-blood values (p less than 0.05, r = 0.80). Operator training to develop a consistent procedure was the most critical factor in achieving accurate and precise results.
منابع مشابه
Pharmacokinetics and Pharmacodynamics of Gliclazide from Immediate and Modified Release Formulation Tablets in Rats
The objective of the study was to compare pharmacokinetic and pharmacodynamic parameters of gliclazide after administration of immediate (IR) and modified release (MR) tablets. The experiment included rats with both normoglyceamia and streptozocin (STZ)-induced hyperglyceamia. Several MR formulations were designed and in vitro drug release profile was assessed by a dissolution test. For the fur...
متن کاملPharmacokinetics and Pharmacodynamics of Gliclazide from Immediate and Modified Release Formulation Tablets in Rats
The objective of the study was to compare pharmacokinetic and pharmacodynamic parameters of gliclazide after administration of immediate (IR) and modified release (MR) tablets. The experiment included rats with both normoglyceamia and streptozocin (STZ)-induced hyperglyceamia. Several MR formulations were designed and in vitro drug release profile was assessed by a dissolution test. For the fur...
متن کاملBlood glucose measurement with Dextrostix and new reflectance meter.
A new instrument, Eyetone, has been produced for use with a Dextrostix reagent strip for estimating blood sugar levels. It differs from the Dextrostix Reflectance Meter in having only one meter scale, a two-point calibration, and a range of measurement limited to 10-400 mg/100 ml. Results with the manufacturers' original calibration were unsatisfactory, but when recalibrated the performance of ...
متن کاملRat Bone Marrow Mesenchymal Stem Cell Differentiation to Insulin Producing Cells and Evaluation their Responses in Vitro and in Vivo
Background In recent years, many researchers haveattempted to cure diabetes by using stem cells technology. Stem cells from different sources have capabilityto differentiateinto insulin producing cells (IPCs) by different methods. The obstaclesof these methods aretheirexpensive materials and complexity ofmethodswhichare practicallydisadvantagesfor producing enough transplantableIPCs that can ...
متن کاملIn vivo evaluation of physiological efficacy of insulin-loaded nanoliposomes prepared for oral delivery
Introduction: Oral delivery is the most favorable route for insulin administration. The aim of this study was to generate new chitosan coated insulin nanoliposomes and then to assess the physiological efficacy of these nanoliposomes after oral administration in diabetic rabbits. Methods: Nanoliposomes with negative surface charge encapsulating insulin were prepared by reverse phase evaporat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 29 3 شماره
صفحات -
تاریخ انتشار 1983