Assessment of the primary rotational stability of uncemented hip stems using an analytical model: Comparison with finite element analyses
نویسندگان
چکیده
BACKGROUND Sufficient primary stability is a prerequisite for the clinical success of cementless implants. Therefore, it is important to have an estimation of the primary stability that can be achieved with new stem designs in a pre-clinical trial. Fast assessment of the primary stability is also useful in the preoperative planning of total hip replacements, and to an even larger extent in intraoperatively custom-made prosthesis systems, which result in a wide variety of stem geometries. METHODS An analytical model is proposed to numerically predict the relative primary stability of cementless hip stems. This analytical approach is based upon the principle of virtual work and a straightforward mechanical model. For five custom-made implant designs, the resistance against axial rotation was assessed through the analytical model as well as through finite element modelling (FEM). RESULTS The analytical approach can be considered as a first attempt to theoretically evaluate the primary stability of hip stems without using FEM, which makes it fast and inexpensive compared to other methods. A reasonable agreement was found in the stability ranking of the stems obtained with both methods. However, due to the simplifying assumptions underlying the analytical model it predicts very rigid stability behaviour: estimated stem rotation was two to three orders of magnitude smaller, compared with the FEM results. CONCLUSION Based on the results of this study, the analytical model might be useful as a comparative tool for the assessment of the primary stability of cementless hip stems.
منابع مشابه
Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملPrimary stability in total hip replacement
BACKGROUND In total hip replacement (THR), it is essential to achieve a primary stability to guarantee good long-term results. A novel locking screw hip (LSH)-stem, anchored to the medial cortex of the proximal femur by 5 monocortical locking screws, was developed to overcome the shortcomings of uncemented press-fit and cemented straight stems while simultaneously achieving primary stability. T...
متن کاملA New Finite Element Formulation for Buckling and Free Vibration Analysis of Timoshenko Beams on Variable Elastic Foundation
In this study, the buckling and free vibration of Timoshenko beams resting on variable elastic foundation analyzed by means of a new finite element formulation. The Winkler model has been applied for elastic foundation. A two-node element with four degrees of freedom is suggested for finite element formulation. Displacement and rotational fields are approximated by cubic and quadratic polynomia...
متن کاملUncemented femoral stem design influences the occurrence rate of postoperative fractures after primary hip arthroplasty: a comparison of the Image and Profile stems.
Two consecutive series of hip arthroplasties with closely similar anatomic uncemented femoral implants [207 Profile (DePuy) and 171 Image (Smith&Nephew) stems] were compared with regard to postoperative femoral fractures. All arthroplasties were performed by senior staff surgeons, mainly on patients below 65 years of age. In the Image group the occurrence rate of postoperative periprosthetic fe...
متن کاملQuantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...