Comparative Study between the Westergren and Automated Method for Determination of the Erythrocyte Sedimentation Rate

نویسنده

  • Viroj Wiwanitkit
چکیده

A comparative study between the standard Westergren and a new automated method for the determination of erythrocyte sedimentation rate (ESR) was performed on 80 individual subjects. From this study, the comparison-of-methods plot automated method (X) and VS Westergren method (Y) gave the least square linear regression equation of Y=0.978 X + 0.64 (r=0.98). Precision analysis gave a coefficient of variation below 3%. At present the new automated method seems to be an effective and safe technique for determination of the erythrocyte sedimentation rate. Chiang Mai Med Bull 2001;40(3):139-141. Suitable and effective techniques for erythrocyte sedimentation rate (ESR) determination are necessary for the success laboratory processes. Several methods to determine the ESR have been developed. Among these, the Westergren method is accepted as a standard technique that has been widely used in Thailand. Although the Westergren method has been popular for its many advantages, the risk to the practitioner regarding contact with blood specimens, which can lead to blood-borne infection, is still high. At present, many new methods to determine the ESR have been developed to decrease the risk. (3) Automated erythrocyte sedimentation determination is an example of newly developed equipment. The automated R tube is a specially designed erythrocyte sedimentation analyzer based on the principle of the electrical impedance of human blood. By using this new technology, the ESR can be easily performed. After application of the collected specimen tube onto the analyzer, determination can be carried out automatically. This new method is currently used in Thailand, but there is no report about its efficacy. Therefore, this study was set as a pilot study to compare this new technique to the Westergren method for determination of ESR. Materials and methods This study was comparative between the classical Westergren and automated method for determination of the ESR. Eighty individual volunteer subjects were included. For each subject, two methods of ESR determination were performed. The first was the Westergren method, which was as standard method, and the second was the automated tube method (Forli Lab, Italy). The automated method was new and made Address requests for reprints: Viroj Wiwanitkit, M.D., Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand. E-mail: [email protected] Wiwanitkit V. เชียงใหม เวชสาร 140 use of the electrical impedance principle. The erythrocyte sedimentation rate for each sample was read, and recorded after 1 hour. All recorded data were collected, analyzed and interpreted. Linear regression was performed in order to assess the significant difference in the ESR obtained by the Westergren and automated methods. Results All 80 samples were analyzed for ESR by the Westergren and automated methods. The data from this study are summarized in Table 1. The average difference in value between both methods was 0.240±0.128 mm/hr (p=0.072). The comparison-ofmethods plot automated method (X) VS Westergren method (Y) gave the least square linear regression equation of Y=0.978 X+ 0.64 (r=0.98) (Figure 1). Using the cut off value of 20 mm/hr, the correlation coefficients were 0.958 (p>0.05) and 0.954 Table 1. Characteristics of samples used in the study. Assays Values (mm/hr)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study between Westergren and modified microhaematocrit method for determination for erythrocyte sedimentation rate

To compare between standard Westergren and modified microhaematocrit method for determination for erythrocyte sedimentation rate Study design: A laboratory method comparative study. Subjects: blood samples from 80 individual subjects. For each subject, two methods for erythrocyte sedimentation rate determination were performed. The first method was the Westergren method as a standard method and...

متن کامل

Aberration of Erythrocyte Sedimentation Rate by Zinc Nanoparticles

Dear Editor, erythrocyte sedimentation rate (ESR) is a useful basic clinical pathology laboratory investigation. It can be helpful in diagnosis and follow-up of several diseases. At present, a new automated method with proven reliability is available for ESR test  (1). Here, the authors report on observation on a laboratory experiment to test the effect of zinc nanoparticles on ESR results. The...

متن کامل

A Comparison Between the StaRRsed Auto-Compact Erythrocyte Sedimentation Rate Instrument and the Westergren Method

BACKGROUND The Westergren method is the golden standard for measuring erythrocyte sedimentation rate (ESR). All ESR methods should agree with the standardized method of the International Council for Standardization in Hematology (ICSH). Citrate samples are commonly used for ESR. This extra sample adds costs and can be inconvenient for the patient. Therefore, some new automated ESR analyzers use...

متن کامل

Erythrocyte sedimentation rate.

In their article entitled: “The decrease in erythrocyte sedimentation rate related to general anesthesia”, Clin Hemorheol Microcirc 35 (2006) 459–462, Caglayan and co-workers have investigated the effects of general anesthetic agents on erythrocyte properties, reflected in changes in the Erythrocyte Sedimentation Rate (ESR). In their introduction the authors referred to the one-hour ESR method ...

متن کامل

Evaluation of sedimentation rate methodology reveals an unusual pediatric subpopulation with lupus or lupus-like syndrome and hemolytic anemia

Purpose Sedimentaion rate is often used to manage pediatric patients with rheumatologic disease. Most management decisions are dependent on studies which have used Wintrobe or Westergren sedimentation rate methodologies. However, these methods suffer from the need for relatively large amounts of blood and long turn-around times. Determination of sedimentation rate using laser kinetic rate deter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001