Intermediate outcome of a cruciate-retaining tibia.

نویسندگان

  • J Wesley Mesko
  • Sara Heath
  • Jianhua Shen
چکیده

The use of an all-polyethylene tibia in total knee arthroplasty is being revisited as a means to decrease backside polyethylene wear and lessen cost. The Depuy Sigma all-polyethylene tibia (Depuy Orthopedics, Warsaw, Indiana) has been reported with good outcomes at a greater than 10-year interval, whereas the Biomet AGC I beam design (Biomet, Warsaw, Indiana) has had a high failure rate at an early interval. This is a retrospective review of another design. One hundred seventy patients (190 cruciate-retaining total knee replacements) with a Scorpio (Stryker, Mahwah, New Jersey) all-polyethylene implant and tibia were identified in the authors' registry. This implant was chosen for all octogenarians deemed fit for a cruciate-retaining knee and a few septuagenarians who were deemed likely to remain inactive postoperatively for reasons other than knee arthritis. Mean follow-up was 38 months (range, 24-83 months). Mean patient age was 83.1 years (range, 72.7-93.8 years). Twenty-seven patients (29 knees) were lost to follow-up. Nineteen patients (24 knees) died before 24-month follow-up; all implants were in place, and no deaths were associated with the index procedure. Fifty-one patients (55 knees) were followed by telephone interview only and 75 patients (81 knees) by an office visit with radiograph analysis. One tibia revision was performed 2 months postoperatively for an implant placed in extension and varus. No infections, component wear, radiolucent lines, or impending revisions of the remaining cohort occurred. Lower Extremity Activity Scale scores ranged from 2 to 10 (mean score, 6.8), which demonstrated success even in patients with an active lifestyle. This previously unreported design is a promising all-polyethylene tibia alternative for total knee arthroplasty in older patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.

Rotating-platform, mobile-bearing total knee arthroplasty was initially developed using a posterior cruciate-sacrificing technique and design. Posterior cruciate-substituting and -retaining, rotating-platform total knee arthroplasty designs were developed later. The purpose of this study was to evaluate a minimum 4-year follow-up of total knee arthroplasty performed with a posterior cruciate-re...

متن کامل

Similar outcome after retention or sacrifice of the posterior cruciate ligament in total knee arthroplasty

The purpose of this study was to answer 2 questions: Does the posterior cruciate ligament (PCL) produce femoral rollback in a single-design, cruciate-sparing total knee arthroplasty (TKA)? Does the PCL prevent posterior tibial displacement when it is retained after a single-design, cruciate-sparing TKA? Knee kinematics and limits of motion were measured with the knees in the following states: (...

متن کامل

Improving maximum flexion with a posterior cruciate retaining total knee arthroplasty: a fluoroscopic study.

Achieving a large range of motion (ROM) is a much-desired clinical outcome after total knee arthroplasty (TKA), especially in Asian and Middle Eastern cultures. TKA design plays an important role in providing the post-operative ROM. This study investigated the kinematics of a new high-flexion posterior cruciate ligament retaining total knee replacement, featuring an enlarged posterior condylar ...

متن کامل

Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants.

Contemporary posterior cruciate-retaining total knee designs have provided pain relief and improved knee function but have failed to reproduce the kinematics and stability of the normal nonarthritic knee. The Medial Pivot total knee design features a near constant radius of curvature of the femoral component. The tibial surface is highly congruent and asymmetric, permitting a medial pivot motio...

متن کامل

Survival analysis of a cementless, cruciate-retaining total knee arthroplasty. Clinical and radiographic assessment 10 to 13 years after surgery.

We performed a prospective study of 54 patients (76 knees) who underwent Osteonics series 3000 cruciate-retaining cementless total knee arthroplasty between December 1990 and June 1993. Five patients (seven knees) were lost to follow-up (90.7% completion). One patient required revision at 10.5 years after operation. The rate of survival was 100% at ten years and 96.7% at 13 years. The mean ten-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 36 7  شماره 

صفحات  -