Early outcomes of proximal humerus fracture fixation with locking plate and intramedullary fibular strut graft.

نویسندگان

  • Edwin Tan
  • Denny Lie
  • M K Wong
چکیده

Proximal humerus fractures are commonly encountered in elderly patients. Surgical treatment demonstrates high complication rates, including varus construct collapse and screw cutout. In this study, the authors evaluate the clinical outcome of locking plate fixation with intramedullary fibular strut graft augmentation as a primary surgical treatment in the prevention of early collapse and screw cutout. A total of 9 patients were evaluated. Surgery was performed for displaced proximal humerus fractures between April and December 2011. Patients were either class 2, 3, or 4, according to Neer classification. Mean patient age was 75.4 years. Preoperative and immediate, 6-week, and 3-month postoperative radiographs were evaluated. Head-shaft angles were measured to assess for varus collapse and displacement. Range of motion, complication rates, and functional recovery were also evaluated. Patients underwent open reduction and internal fixation with placement of an intramedullary fibular strut graft. Fixation was achieved with a Philos plate (Synthes, Oberdorf, Switzerland). Reduction and fixation were evaluated with radiographs. Passive exercises and range of motion were allowed immediately postoperatively, and all patients achieved active abduction and forward flexion 6 weeks postoperatively. Shoulder radiographs taken 12 weeks postoperatively revealed no loss of reduction or screw cutout. The introduction of the locking plate has improved outcomes. The addition of an intramedullary strut graft has shown improved preliminary results. Maintained reduction was observed in all 9 patients in the early postoperative period, and good functional motion was achieved. No incidence of screw cutout was recorded.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus.

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1,000,000 cycles. Immediately...

متن کامل

Fibular Strut Graft Augmentation for Open Reduction and Internal Fixation of Proximal Humerus Fractures

BACKGROUND Proximal humerus fractures are common problems plaguing the elderly population. PURPOSE The purposes of this study were to determine the outcomes of fibular strut allografts in treatment of proximal humerus fractures with open reduction internal fixation (ORIF) and to present the authors' preferred surgical technique. The hypothesis was that the use of fibular strut allografts in t...

متن کامل

Proximal humeral nonunion treated with an intramedullary tantalum cylinder.

Nonunion is uncommon after proximal humerus fracture surgery. There is no agreement about preferred method of treatment. Traditional approaches have included laterally based locking plates, autogenous grafting, and endosteal support to provide improved biomechanical stability. Open reduction and internal fixation (ORIF) of proximal humeral nonunion has been performed with various methods, inclu...

متن کامل

Non-vascularised fibular graft as an intramedullary strut for infected non-union of the humerus.

PURPOSE. To review outcomes of 7 patients who underwent revision surgery for infected non-union of the humerus using a fibular graft as an intramedullary strut. METHODS. Records of 7 men aged 29 to 59 (mean, 40) years with humeral diaphyseal infected non-union who underwent fixation using a compression plate and a non-vascularised fibular graft as an intramedullary strut were reviewed. The mean...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 9  شماره 

صفحات  -

تاریخ انتشار 2014