Using dynamic low-coherence interferometry to image Brownian motion within highly scattering media.

نویسندگان

  • D A Boas
  • K K Bizheva
  • A M Siegel
چکیده

Dynamic low-coherence interferometry was used to measure Brownian motion of submicrometer particles within highly scattering media. Strong rejection of multiply scattered light was obtained by combination of a coherence gate with a confocal microscope, thus allowing particle characterization methods generally reserved for optically dilute materials to be applied to optically concentrated suspensions. The Brownian diffusion coefficient of highly scattering media was determined with an accuracy better than 5%. Furthermore, we show that spatial variations in the Brownian diffusion coefficient can be imaged with an axial resolution determined by the coherence length of the light source (~30 mum) . The experiments also show broadening of the power spectrum as a function of depth into the sample, most likely as a result of detecting multiply scattered light.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Path-length-resolved dynamic light scattering in highly scattering random media: The transition to diffusing wave spectroscopy

We used low coherence interferometry to measure Brownian motion within highly scattering random media. A coherence gate was applied to resolve the optical path-length distribution and to separate ballistic from diffusive light. Our experimental analysis provides details on the transition from single scattering to light diffusion and its dependence on the system parameters. We found that the tra...

متن کامل

Path-length-resolved dynamic light scattering: modeling the transition from single to diffusive scattering.

Dynamic light-scattering spectroscopy is used to study Brownian motion within highly scattering samples. The fluctuations of the light field that is backscattered by a suspension of polystyrene microspheres are measured as power spectra by use of low-coherence interferometry to obtain path-length resolution. The data are modeled as the sum of contributions to the detected light weighted by a Po...

متن کامل

Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media.

An optical Doppler tomography (ODT) system that permits imaging of fluid flow velocity in highly scattering media is described. ODT combines Doppler velocimetry with the high spatial resolution of low-coherence optical interferometry to measure fluid flow velocity at discrete spatial locations. Tomographic imaging of particle flow velocity within a circular conduit submerged 1 mm below the surf...

متن کامل

Low-coherence heterodyne photon correlation spectroscopy.

Photon correlation spectroscopy (PCS) is routinely used to investigate the dynamics of colloidal particles undergoing Brownian motion. This technique is applicable to low-density colloidal suspensions in which the effects of multiple light scattering are minimal. We introduce a new low-coherence heterodyne PCS technique that allows direct investigation of colloidal suspensions of higher concent...

متن کامل

Diffusion of Temporal Field Correlation with Selected Applications

We consider· the transport of the electric field temporal autocorrelation in heterogeneous, fluctuating turbid media. Experiments are performed in strongly scattering media with spatially separated static and dynamic components, and low resolution "dynamical" images of such media are obtained using autocorrelation measurements of the emerging speckle fields taken along the sample surface. Our a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 1998