Effect of microgravity and hypergravity on deposition of 0.5- to 3-micron-diameter aerosol in the human lung.
نویسندگان
چکیده
We measured intrapulmonary deposition of 0. 5-, 1-, 2-, and 3-micron-diameter particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and at approximately 1.6 G. Subjects breathed aerosols at a constant flow rate (0.4 l/s) and tidal volume (0.75 liter). At 1 G and approximately 1.6 G, deposition increased with increasing particle size. In microG, differences in deposition as a function of particle size were almost abolished. Deposition was a nearly linear function of the G level for 2- and 3-micron-diameter particles, whereas for 0.5- and 1.0-micron-diameter particles, deposition increased less between microG and 1 G than between 1 G and approximately 1.6 G. Comparison with numerical predictions showed good agreement for 1-, 2-, and 3-micron-diameter particles at 1 and approximately 1.6 G, whereas the model consistently underestimated deposition in microG. The higher deposition observed in microG compared with model predictions might be explained by a larger deposition by diffusion because of a higher alveolar concentration of aerosol in microG and to the nonreversibility of the flow, causing additional mixing of the aerosols.
منابع مشابه
Reduced Gravity and Aerosol Deposition in the Human Lung
provides an overview of those studies as a basis for the consideration of aerosol deposition in the reduced gravity of Mars. Overall deposition: We first performed total deposition studies of 0.5-3 μm-diameter particles in normal gravity (1G), microgravity (μG) and hypergravity (~1.6G) using the NASA Microgravity Research Aircraft [2]. Subjects continuously breathed aerosol from a reservoir at ...
متن کاملDeposition and dispersion of 1-μm aerosol boluses in the human lung: effect of micro- and hypergravity
Darquenne, Chantal, John B. West, and G. Kim Prisk. Deposition and dispersion of 1-μm aerosol boluses in the human lung: effect of microand hypergravity. J. Appl. Physiol. 85(4): 1252–1259, 1998.—We performed bolus inhalations of 1-μm particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (μG) and in ,1.6 G. Boluses of ,70 ml were inhaled at different p...
متن کاملEffect of small flow reversals on aerosol mixing in the alveolar region of the human lung.
It has been suggested that irreversibility of alveolar flow combined with a stretched and folded pattern of streamlines can lead to a sudden increase in mixing in the lung. To determine whether this phenomenon is operative in the human lung in vivo, we performed a series of bolus studies with a protocol designed to induce complex folding patterns. Boli of 0.5- and 1-microm-diameter particles we...
متن کاملEffect of gravity on aerosol dispersion and deposition in the human lung after periods of breath holding.
To determine the extent of the role that gravity plays in dispersion and deposition during breath holds, we performed aerosol bolus inhalations of 1-microm-diameter particles followed by breath holds of various lengths on four subjects on the ground (1G) and during short periods of microgravity (microG). Boluses of approximately 70 ml were inhaled to penetration volumes (V(p)) of 150 and 500 ml...
متن کاملRegional deposition of inhaled particles in human lungs: comparison between men and women.
We measured detailed regional deposition patterns of inhaled particles in healthy adult male (n = 11; 25 +/- 4 yr of age) and female (n = 11; 25 +/- 3 yr of age) subjects by means of a serial bolus aerosol delivery technique for monodisperse fine [particle diameter (Dp) = 1 micron] and coarse aerosols (Dp = 3 and 5 micron). The bolus aerosol (40 ml half-width) was delivered to a specific volume...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 83 6 شماره
صفحات -