Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components.
نویسندگان
چکیده
The accuracy of estimating the relative pose between knee replacement components, in terms of clinical motion, is important in the study of knee joint kinematics. The objective of this study was to determine the accuracy of the single-plane fluoroscopy method in calculating the relative pose between the femoral component and the tibial component, along knee motion axes, while the components were in motion relative to one another. The kinematics of total knee replacement components were determined in vitro using two simultaneous methods: single-plane fluoroscopic shape matching and an optoelectronic motion tracking system. The largest mean differences in relative pose between the two methods for any testing condition were 2.1°, 0.3°, and 1.1° in extension, abduction, and internal rotation respectively, and 1.3, 0.9, and 1.9 mm in anterior, distal, and lateral translations, respectively. For the optimized position of the components during dynamic trials, the limits of agreement, between which 95% of differences can be expected to fall, were -2.9 to 4.5° in flexion, -0.9 to 1.5° in abduction, -2.4 to 2.1° in external rotation, -2.0 to 3.9 mm in anterior-posterior translation, -2.2 to 0.4mm in distal-proximal translation and -7.2 to 8.6mm in medial-lateral translation. These mean accuracy values and limits of agreement can be used to determine whether the shape-matching approach using single-plane fluoroscopic images is sufficiently accurate for an intended motion tracking application.
منابع مشابه
Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کامل"In vivo" pose estimation of artificial knee implants using computer vision.
This paper describes an algorithm to estimate the position and orientation (pose) of artificial knee implants from fluoroscopy images using computer vision. The resulting information is used to determine contact position from " in vivo" bone motion in implanted knees. This determination can be used to support the development of improved prosthetic knee implants. Current generation implants have...
متن کاملThree-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.
OBJECTIVE: A method has been developed to accurately measure three-dimensional (3-D) femoral-tibial contact positions of artificial knee implants in vivo from X-ray fluoroscopy images using interactive 3-D computer vision algorithms. DESIGN: A computerized graphical (CAD) model of an implant component is displayed as an overlay on the original X-ray image. An image matching algorithm matches th...
متن کاملKnee Kinematic Improvement After Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method
Objectives: The aim of this study was to extract suitable spatiotemporal and kinematic parameters to determine how Total Knee Replacement (TKR) alters patients’ knee kinematics during gait, using a rapid and simplified quantitative two-dimensional gait analysis procedure. Methods: Two-dimensional kinematic gait pattern of 10 participants were collected before and after the TKR surgery,...
متن کاملPose estimation of artificial knee implants in fluoroscopy images using a template matching technique
This paper describes an algorithm to estimate the position and orientation (pose) of artificial knee implants from X-ray fluoroscopy images using computer vision. The resulting information is used to determine the kinematics of bone motion in implanted knees. This determination can be used to support the development of improved prosthetic knee implants, which currently have a limited life span ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 44 4 شماره
صفحات -