Prevention of air leakage by spraying vivostat fibrin sealant after lung resection in pigs.

نویسندگان

  • H K Kjaergard
  • J H Pedersen
  • M Krasnik
  • U S Weis-Fogh
  • H Fleron
  • H E Griffin
چکیده

STUDY OBJECTIVES To evaluate Vivostat fibrin sealant in the prevention of air leakage after experimental lung resection in pigs. DESIGN Randomized study. SETTING University laboratory. METHODS Six Landrace pigs were operated on in both lungs through a median sternotomy. Five different resection sites were created in each lung. INTERVENTION Randomization was performed to either application of Vivostat fibrin sealant (ConvaTec; Skillman NJ) or human albumin 20% (control) at the resection sites. The lung parenchyma was occluded with a soft clamp for either 1, 2, 5, or 10 min in the treatment group and 10 min in the control group. After removal of the clamp, the lung was ventilated with an increasing intrabronchial pressure of 20, 30, and 45 cm H(2)O for 2 min at each step. RESULTS At inspiratory pressures of 20 and 30 cm H(2)O air leaks were found in the control group but not in the Vivostat group (p < 0.001). At an inspiratory pressure of 45 cm H(2)O, there were two small air leaks in the Vivostat group at each clamping time (four at 5 min), compared with five small and seven large leaks in the control group. Analysis of the data after 10 min of clamping showed that the Vivostat group was superior to the human albumin group (p = 0.002). CONCLUSIONS This randomized study shows that Vivostat fibrin sealant is effective in preventing air leakage after small lung resections in pigs, even at high inspiratory pressures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure

BACKGROUND Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat(®) system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. METHODS From January 2012 to March 2014, 77 patien...

متن کامل

The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage

Objectives: The combination of fibrin sealant and bioabsorbable sheet is known to provide a better sealing effect on alveolar air leakage compared to the single use of fibrin sealant. However, there is little evidence that reveals the optimum techniques for their combined application. Presently we developed a novel Rub + Soak B method that comprises the attachment of thrombin-impregnated sheet ...

متن کامل

Technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage.

OBJECTIVES The combination of fibrin sealant and bioabsorbable sheet is known to provide a better sealing effect on alveolar air leakage compared to the single use of fibrin sealant. However, there is little evidence that reveals the optimum techniques for their combined application. Presently we developed a novel Rub + Soak B method that comprises the attachment of thrombin-impregnated sheet t...

متن کامل

Fibrin sealant for prevention of resection surface-related complications after liver resection: a randomized controlled trial.

OBJECTIVE To evaluate the efficacy of fibrin sealant in reducing resection surface-related complications in liver surgery. BACKGROUND Bile leakage, bleeding, and abscess formation are major resection surface-related complications after liver resection. It is unclear whether application of fibrin sealant to the resection surface is effective in reducing these complications. METHODS In a mult...

متن کامل

Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.

BACKGROUND Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. METHODS Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 117 4  شماره 

صفحات  -

تاریخ انتشار 2000