An Automatic Selective Level Measuring

نویسنده

  • Reid Urquhart
چکیده

AKING RELIABLE MEASUREMENTS ON fTE-quency-division multiplexed (FDM) baseband signals presents a two-part problem. First, the frequency at which the measurement is to be made must be determined. Then second, the measurement must be made with high accuracy in the presence of numerous interfering signals. At first sight the choice of a measurement frequency may seem to be a trivial problem, but finding the center frequency of a particular channel in a communications system that may have as many as 3600 channels is no easy task and could, in fact, occupy more time than making the actual measurement itself. A maintenance engineer may wish, for example, to measure channel 3 in group 2 of supergroup 13 in mastergroup 5 without having any idea of where in the frequency spectrum that channel may lie. The only way to find out has been through the use of large charts that describe the FDM plan, such as the one shown in part in Fig. 1. Usually these only show each channel's carrier frequency, so the engineer must derive the center frequency ofthe sideband occupying the channel in order to proceed with the measurement. Besides the time taken to hunt for a particular channel's frequency, such an arrangement leads to the possibility of frequent errors. The problem of translating the FDM description of a channel into a tuning frequency has now been eliminated by a new selective level measuring set (SLMS), the Hewlett-Packard Model 3745AlB (Fig. z). This instrument has all the details of FDM plans stored in read-only memories. The stored plans are accessed by special keys, so the user merely enters the specifics of a certain channel (channel number, group number, etc.J by way of the keys, and the instrument then automatically tunes itself so the 3.1-kHz filter covers the active region of that channel exactly. It then makes a true-rms measurement of the power in that channel Printed n U.S A. and displays the results, including the frequency to which it is tuned. on numeric indicators. Furthermore , the instrument is completely autoranging over a 140-dB range, so it displays results directly without the need for setting attenuators manually. Cover: Picking one particular channel out of a babble of thousands of frequency-multiplexed communications channels is greatlY simplified by a new selective level measuring set that talks the language of the telephone engineer. Microprocessor control is the key to this new ability, as …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integration of Visible Image and LIDAR Altimetric Data for Semi-Automatic Detection and Measuring the Boundari of Features

This paper presents a new method for detecting the features using LiDAR data and visible images. The proposed features detection algorithm has the lowest dependency on region and the type of sensor used for imaging, and about any input LiDAR and image data, including visible bands (red, green and blue) with high spatial resolution, identify features with acceptable accuracy. In the proposed app...

متن کامل

Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio

 Objective(s): Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H215O positron emission tomography. Clarification of differences in r...

متن کامل

Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method

Evaluations of the acidity or alkalinity of solutions are used in many industries such as food industries, medicine, chemical engineering, petrochemical industries, agriculture, animal husbandry, industrial laboratories, etc. Portable and stationary pH measurements are very common and are an integral part of these studies, due to the importance of pH. In most of these evaluations and studies, a...

متن کامل

A Semi-Automatic Algorithm for Estimating Cobb Angle

Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...

متن کامل

A computer-controlled multi-electrode switch

A computer-actuated switch was built to control, simultaneously, two automatic titration assemblies each consisting of an electrode pair and a burette, and using only one measuring device. This switch is modular, simple and versatile allowing easy adaptation and expansion; apart from its application in multiple-titration systems, this device can also be used for standard addition analysis and m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1976