BACKGROUND Radiostereometric analysis (RSA) is often used for evaluating implanted devices over time. Following patients who have had tantalum beads implanted as markers in conjunction with joint replacements is important for longitudinal evaluation of these patients and for those with similar implants. As doing traditional RSA imaging is exacting and limited to specialized centers, it is important to consider alternative techniques for this ongoing evaluation. This paper studies the use of computed tomography (CT) to evaluate over time tantalum beads which have been implanted as markers. METHODS The project uses both a hip model implanted with tantalum beads, acquired in several orientations, at two different CT energy levels, and a cohort of seven patients. The model was evaluated twice by the same observer with a 1-week interval. All CT volumes were analyzed using a semi-automated 3D volume fusion (spatial registration) tool which provides landmark-based fusion of two volumes, registering a target volume with a reference volume using a rigid body 3D algorithm. The mean registration errors as well as the accuracy and repeatability of the method were evaluated. RESULTS The mean registration error, maximum value of repeatability, and accuracy for the relative movement in the model were 0.16 mm, 0.02° and 0.1 mm, and 0.36° and 0.13 mm for 120 kVp and 0.21 mm, 0.04° and 0.01 mm, and 0.39° and 0.12 mm for 100 kVp. For the patients, the mean registration errors per patient ranged from 0.08 to 0.35 mm. These results are comparable to those in typical clinical RSA trials. This technique successfully evaluated two patients who would have been lost from the cohort if only RSA were used. CONCLUSIONS The proposed technique can be used to evaluate patients with tantalum beads over time without the need for stereoradiographs. Further, the effective dose associated with CT is decreasing.
منابع مشابه
Pelvic Incidence in Patients with Hip Osteoarthritis
Background: Hip osteoarthritis (OA) is a major cause of pain and disability that results in considerable social and medical costs. Mechanics such as posture, alignment and orientation of the hips and the spinal column and the relationship between these factors have been implicated in the development of both hip and spine pathologies. This study aims to test the hypothesis if pelvic incidenc...
متن کاملClinical Impact of 18F-FDG PET/CT on the Management of Gynecologic Cancers: One Center Experience
Objective(s): We aim to investigate the clinical impact of 18F-FDG PET/CT in managing patients with gynecological malignancies and pelvic or extrapelvic lymph nodes that are of equivocal significance on conventional imaging.Methods: We retrospectively evaluated 18F-FDG PET/CT scans of patients with gynecologic tumors who were referred to King Hussein Cancer Center from January 2010 to August 20...
متن کاملComparing Unilateral and Bilateral Total Knee Replacement Based on the Functional Approach
Purpose: Total Knee Replacement (TKR) is the treatment of choice for severe osteoarthritis with acceptable outcomes regarding pain management, function and quality of life enhancement. Because many patients require TKR procedure for their both knees, there has always been a challenge in the choice of simultaneous or consecutive operations. The aim of the present study was to compare the t...
متن کاملThe Effects Of Interfacial Roughness On The Argon Ion Implanted Tantalum Films
In the present study, effect of interfacial roughness on the ion implanted Tantalum based surfaces has been investigated. The argon ions with energy of 30 keV and in doses of 1×1017 , 3×1017 , 5×1017 , 7×1017 , and 10×1017 (ion/cm2) have been used at ambient temperature. The Atomic Force Microscopy (AFM), analysis have been used to study and characterize the surfaces morphology. The effect of ...
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016