Beyond Copper: MR Imaging with Carbon Nanotube Receiver Coils

نویسندگان

  • R. Viswanathan
  • B. Goldstein
  • K. Anderson
  • M. Bronskill
  • R. Baughman
  • M. Zhang
  • S. Fang
  • A. Zakhidov
  • A. Aliev
چکیده

Introduction Recent advances in nanotechnology have heralded new processes for fabrication of nanomaterials having macroscopic dimensions. A solid-state process for producing macroscopic sheets made of carbon nanotubes has been reported in [1]. The technological promise of carbon nanotubes includes charge transport with minimal scattering, leading to expectations of large electrical conductivity or low electrical resistance. As is well known, at high frequencies (usually over 10 KHz for practical purposes) metallic conductors display an increasing resistance with frequency due to the skin effect that confines current density to a surface layer of the conductor. In contrast, it was shown in [2] that the skin depth of bulk carbon nanotube material is large. The reduced cross section for electron transport in metals leads to a significantly higher resistance at high frequencies as compared to the DC resistance. Additionally, when formed into a receiver coil device for signal reception purposes, its effective resistance demonstrates further increases due to interactions between current densities in adjacent turns or adjacent portions of conductors, a phenomenon often termed the proximity effect. Typically, this behavior generates constraints on coil imaging performance. Here we describe the first construction of a MR imaging coil made of carbon nanotube conductor that does not display such effects, at least within frequency ranges relevant for medical magnetic resonance imaging, leading directly to prospects of significant enhancements in SNR and image quality. Materials and Methods A “carpet” of carbon nanotubes of uniform height was grown in the form of a forest over a catalyzed silicon wafer with a furnace process, as described in [1]. The forest was drawn into a continuous, macroscopic carbon nanotube sheet of width 3 cm. The DC electrical resistance of an individual nanotube sheet was measured to be of the order of 700 ohms per square, as in [1], still quite high in comparison to metallic sheets with the same sheet thickness. In order to reduce the resistance, we formed a layered structure of sheets by winding the sheet on a drum. In this manner we obtained an effective ribbon structure made of a stack of 80 sheets or layers. The stack was densified by ethanol application to obtain a ribbon thickness of approximately 4 microns. The ribbon was 3 cm wide with a length of about 21.5 cm, sufficient to wrap approximately twice around a test tube of diameter 3 cm. Gold-plated copper electrodes were attached to the ends of the ribbon and mounted on a specially built circuit board for electrical characterization to 200 MHz using a Vector Network Analyzer. Next, the ribbon was laid on a 1 mm-thick foam substrate and wrapped twice around a 3 cm diameter test tube to form a coil. Tuning and impedance matching circuitry was built and attached to the coil to produce a resonant circuit tuned to yield close to 50 ohms of impedance with negligible imaginary part at 127.7 MHz, which was suitable for connection of the coil to a 3 Tesla MRI system via a coaxial cable. Results With this (parallel) arrangement of nanotube sheets, the single-sheet DC resistance value of 700 ohms/square is expected to translate to a ribbon resistance of 63 ohms, a value confirmed by direct measurement. In contrast to metals, resistance of the layered stack or ribbon composed of nanotube sheets demonstrated only a small dependence on frequency over the 5 – 130 MHz range relevant to commercially available magnetic resonance imaging systems, as shown in Figure 1. The increasing trend in the resistance can be attributed to capacitive effects. The coil was used to initially image a saline solution to confirm a good SNR response. Subsequently a mouse was inserted into the test tube and imaged with the coil.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

New horizons in MR technology: RF coil designs and trends.

Parallel imaging techniques have developed very rapidly, and realization of their full potential has required the design of magnetic resonance (MR) scanners with ever-increasing numbers of receiver channels (32 to 128). In particular, 1.5- and 3-Tesla fast MR imaging applications are now used in everyday clinical practice. Both strengths require maximum achievable signal-to-noise ratio (SNR) an...

متن کامل

Superconducting RF Coils for Clinical MR Imaging at Low Field1

Rationale and Objectives. A number of recent reports in the MRI literature have established that substantial signal-tonoise ratio (SNR) gains can be achieved with small samples or low resonance frequencies, through the use of high-quality factor high-temperature superconducting (HTS) RF receive coils. We show the application of HTS coils to the imaging of human subjects with improved SNR compar...

متن کامل

Title Superconducting receiver coils for sodium magnetic resonance imaging

We present the results from sodium magnetic resonance imaging (MRI) experiments using high-temperature superconducting (HTS) receiver coils. Sodium imaging has been shown to have great potential for the assessment of cell integrity but suffers from a substantially lower signal-to-noise ratio (SNR) than that of hydrogen imaging. The use of an HTS receiver coil was found to significantly increase...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008