Drift Chamber Vertex Detectors for Slc/lep*
نویسنده
چکیده
منابع مشابه
The 4th Concept Detector for the International Linear Collider
The 4th Concept detector presently being designed for the International Linear Collider introduces several innovations in order to achieve the necessary experimental goal of a detecter that is 2-to-10 times better than the already excellent SLC and LEP detectors. We introduce a dual-readout calorimeter system, a cluster counting drift chamber, and a second solenoid to return the magnetic flux w...
متن کاملFull Simulation Studies of the Silicon Tracker for the Linear Collider Detector ∗
A central tracker based on silicon microstrip sensors has been envisaged for the e + e − linear collider experiments. A full simulation program based on GEANT4 has been developed to study performance of the tracker. We report some preliminary results obtained using this program. The use of silicon microstrip detectors as precise tracking devices in colliding-beam experiments has been well estab...
متن کاملLimits on the Accuracy of Drift Chambers and Calibration Beams
years from now. The understanding of intrinsic limits on the spatial accuracy of drift chambers, and the development of new methods for calibrating them, are therefore still relevant. The present talk attempts to review the state of the art. In order to see what are the main questions to be asked, I have summarized in Table 1 the main characteristics of the drift-chamber detectors proposed for ...
متن کاملA Compact Beam Profile Probe Using Carbon Fibres’ C.Field, N.Hower’, and B.Scott
A beam profile monitor based on the use of carbon fibres is described. It has been designed to be compatible with the operation of the Mark II particle detector at the SLC, I including high resolution secondary vertex detectors mounted 25 mm radially from the beam. f Thin wire or fibre probes are in use at many accelerators to allow the measurement of beam profiles and positions [l]. In particu...
متن کاملThe Time Expansion Chamber as High Precision Drift Chamber
With the principle of the time expansion chamber and the additional measurement of the position of the avalanche along the circumference of the anode wire it is possible to reconstruct the spatial distribution of the primary ionization in space. A position resolution for minimum ionizing tracks of a 5 30 urn is expected. First tests and concepts for vertex detectors are presented.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1987