The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: a study in human cadaveric knees.

نویسندگان

  • Arthur Huang
  • M L Hull
  • Stephen M Howell
چکیده

This study addressed the question of whether the level of compressive load would affect the conclusions from statistical analyses aimed at determining how well a lateral meniscal autograft restores tibial contact (as indicated by the maximum contact pressure, mean pressure, and contact area) to that of the intact knee. If statistical analyses indicated that normal tibial contact was not restored with a higher, more physiologic load, then a secondary question was whether an autograft surgically implanted with bone plugs would improve tibial contact compared to that in a meniscectomized knee. Nine, fresh-frozen human cadaveric knees were subjected to a low, non-physiologic compressive load of 400 N and a higher, more physiologic compressive load of 1200 N under three conditions (lateral meniscus intact, lateral meniscus removed and reimplanted as an autograft, and lateral meniscus removed). Contact pressure on the lateral plateau was measured with pressure sensitive film at 0 degrees, 15 degrees, 30 degrees, and 45 degrees of flexion. At 400 N, p-values from statistical analyses indicated that both the maximum and mean pressures with the autograft were comparable to those of the intact knee (p> or =0.685). However, at 1200 N, p-values from statistical analyses indicated that both the maximum and mean pressures with the autograft were significantly greater than those of the intact knee (p< or =0.0001). Therefore studies designed to evaluate tibial contact pressure for a meniscal transplant should use a higher, more physiologic compressive load, because lower loads overestimate the transplant's effectiveness. Although none of the contact variables was restored to normal when the compressive load was increased to 1200 N, all of the contact variables were more normal than those of the meniscectomized knee. Thus, lateral meniscal allografts implanted using bone plugs can significantly improve contact pressure relative to a meniscectomized knee at the time of implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonanatomic location of the posterior horn of a medial meniscal autograft implanted in a cadaveric knee adversely affects the pressure distribution on the tibial plateau.

Nonanatomic placement of the posterior horn may occur during arthroscopic implantation of a meniscal transplant. The objective of this study was to determine whether nonantomic placement adversely affects the contact pressure distribution on the medial tibial plateau. Medial meniscal autografts were placed in eight cadaveric knees with the posterior horn tunnel in nonanatomic locations (5 mm me...

متن کامل

Identification of cross-sectional parameters of lateral meniscal allografts that predict tibial contact pressure in human cadaveric knees.

To guide the development of improved procedures for selecting meniscal allografts, the objective of this study was to identify which cross-sectional parameters of a lateral meniscal allograft predict the contact pressure of the articular surface of the tibia. To meet the objective, the contact pressure of the articular surface of the tibia was measured with a lateral meniscal autograft and a la...

متن کامل

Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft. A human cadaveric study.

The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an...

متن کامل

Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints.

BACKGROUND A mismatch of the original lateral meniscus and a lateral meniscus allograft by inaccurate preoperative radiographic sizing can have significant consequences on ultimate function. HYPOTHESIS The size of a lateral meniscal allograft affects the contact mechanics of the femoral condyle on the tibial plateau. STUDY DESIGN Controlled laboratory study. METHODS Four right and 2 left ...

متن کامل

Contact Mechanics of the Medial

The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2003