Multicentre evaluation of the diagnostic value of cardiac troponin T, CK-MB mass, and myoglobin for assessing patients with suspected acute coronary syndromes in routine clinical practice.

نویسندگان

  • P O Collinson
  • P J Stubbs
  • A-C Kessler
چکیده

OBJECTIVE To assess the diagnostic efficiency of the third generation cardiac troponin T assay in routine clinical practice. DESIGN Prospective observational study of unselected consecutive admissions. SETTING Multicentre study in 43 teaching and non-teaching hospitals in 13 countries. SUBJECTS 1105 hospital admissions, median age 67 years (range 15-96 years, 63.7% male) with suspected acute coronary syndromes (72.3% of cases) or other non-specific symptoms where cardiac disease required exclusion (27.7%). INTERVENTIONS Over the study period, myoglobin, creatine kinase MB isoenzyme (CK-MB), and cardiac troponin T where measured in parallel with conventional diagnostic tests. Final diagnostic classification involved standard ECG changes and CK-MB mass exceeding 5.0 microg/l. MAIN OUTCOME MEASURES Diagnostic efficiency was assessed by receiver operator characteristic curve analysis including and excluding patients with unstable angina. RESULTS Measurement of cardiac troponin T was diagnostically equivalent to CK-MB and both were better than myoglobin, with areas under the curve at 12 hours of 0.94, 0.99, and 0.80, respectively. Diagnostic criteria using CK-MB were inadequate and showed bias when patients with unstable angina were included. Elevations of cardiac troponin T did not occur when cardiac disease could be categorically excluded but were found in clinical conditions other than suspected acute coronary syndromes. CONCLUSIONS CK-MB is unsuitable as a diagnostic gold standard even at the proposed lower threshold. A lower cut off for cardiac troponin T of 0.05 microg/l should be used for diagnosis of acute myocardial infarction. Diagnosis of acute myocardial infarction cannot be made solely on the basis of a cardiac troponin T result.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Multicentre evaluation of the diagnostic value of cardiac troponin T, CK-MB mass, and myoglobin for assessing patients with suspected acute coronary syndromes in routine clinical practice

Objective: To assess the diagnostic efficiency of the third generation cardiac troponin T assay in routine clinical practice. Design: Prospective observational study of unselected consecutive admissions. Setting: Multicentre study in 43 teaching and non-teaching hospitals in 13 countries. Subjects: 1105 hospital admissions, median age 67 years (range 15–96 years, 63.7% male) with suspected acut...

متن کامل

Cardiac enzyme in emergency medicine

Objective: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Chest pain due to suspected Acute Coronary Syndrome (ACS) is responsible for a large and ijncreasing number of hospital attendances and admissions. Current practice for suspected ACS involves troponin testing 10–12 hours after symptom o...

متن کامل

In vivo inhibitory effect of anti-muscarinic autoantibodies on the parasympathetic function in Chagas disease.

[1] Shave RE, Whyte GP, George K, Gaze DC, Collinson PO. Prolonged exercise should be considered alongside typical symptoms of acute myocardial infarction when evaluating increases in cardiac troponin T. Heart 2005;91:1219–20. [2] Middleton N, George K, Whyte G, Gaze D, Collinson P, Shave R. Cardiac troponin T release is stimulated by endurance exercise in healthy humans. J Am Coll Cardiol 2008...

متن کامل

Multi-Marker Approach with the Use of Biochip Cardiac Array Technology for Early Diagnosis in Patients with Acute Coronary Syndromes

INTRODUCTION Diagnosis of acute coronary syndrome (ACS) is frequently a challenging task while immediate risk stratification remains crucial for the prompt implementation of appropriate therapy in this setting. The prolonged release pattern of both CK-MB mass and cardiac troponins makes it difficult to identify the origin of recent chest pain, thus a combination of early and later biomarkers mi...

متن کامل

Time-dependent diagnostic performance of a rapid troponin T version 2 bedside test in patients with acute coronary syndromes.

In a prospective trial, the diagnostic performance of the second version of the troponin T rapid assay (Trop T; cutoff 0.2 microg/L) was compared with the quantitative cardiac-specific troponin T assay (cTnT ELISA; cutoff 0.1 microg/L) and other established cardiac markers such as CK, CK-MB activity, CK-MB mass and myoglobin. Additionally, a 30-day follow-up was performed to determine the suita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 2003