Electrically detected magnetic resonance in a W-band microwave cavity.
نویسندگان
چکیده
We describe a low-temperature sample probe for the electrical detection of magnetic resonance in a resonant W-band (94 GHz) microwave cavity. The advantages of this approach are demonstrated by experiments on silicon field-effect transistors. A comparison with conventional low-frequency measurements at X-band (9.7 GHz) on the same devices reveals an up to 100-fold enhancement of the signal intensity. In addition, resonance lines that are unresolved at X-band are clearly separated in the W-band measurements. Electrically detected magnetic resonance at high magnetic fields and high microwave frequencies is therefore a very sensitive technique for studying electron spins with an enhanced spectral resolution and sensitivity.
منابع مشابه
Electrically detected magnetic resonance of neutral donors interacting with a two-dimensional electron gas.
We have measured the electrically detected magnetic resonance of donor-doped silicon field-effect transistors in resonant X- (9.7 GHz) and W-band (94 GHz) microwave cavities. The two-dimensional electron gas resonance signal increases by 2 orders of magnitude from X to W band, while the donor resonance signals are enhanced by over 1 order of magnitude. Bolometric effects and spin-dependent scat...
متن کاملMulti-frequency EDMR applied to microcrystalline thin-film silicon solar cells.
Pulsed multi-frequency electrically detected magnetic resonance (EDMR) at X-, Q- and W-Band (9.7, 34, and 94GHz) was applied to investigate paramagnetic centers in microcrystalline silicon thin-film solar cells under illumination. The EDMR spectra are decomposed into resonances of conduction band tail states (e states) and phosphorus donor states (P states) from the amorphous layer and localize...
متن کاملBipolaron formation in organic solar cells observed by pulsed electrically detected magnetic resonance.
We report the observation of a spin-dependent dark transport current, exhibiting spin coherence at room temperature, in a π-conjugated polymer-fullerene blend using pulsed electrically detected magnetic resonance. The resonance at g = 2.0028(3) is due to polarons in the polymer, and exhibits spin locking at high microwave fields. The presence of an excess of fullerene, and the operating voltage...
متن کاملResonant microwave cavity for 8.5-12 GHz optically detected electron spin resonance with simultaneous nuclear magnetic resonance.
We present a newly developed microwave resonant cavity for use in optically detected magnetic resonance (ODMR) experiments. The cylindrical quasi-TE(011) mode cavity is designed to fit in a 1 in. magnet bore to allow the sample to be optically accessed and to have an adjustable resonant frequency between 8.5 and 12 GHz. The cavity uses cylinders of high dielectric material, so-called "dielectri...
متن کاملEnhanced EPR sensitivity from a ferroelectric cavity insert.
We report the development of a simple ferroelectric cavity insert that increases the electron paramagnetic resonance (EPR) sensitivity by an order of magnitude when a sample is placed within it. The insert is a hollow cylinder (length 4.8 mm, outside diameter 1.7 mm, inside diameter 0.6 mm) made from a single crystal of KTaO(3), which has a dielectric constant of 230 at X-band (9.5 GHz). Its ou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 82 3 شماره
صفحات -
تاریخ انتشار 2011