A comparative evaluation of effect of modern-curing lights and curing modes on conventional and novel-resin monomers

نویسندگان

  • Konda Karthik Roy
  • Kanumuru Pavan Kumar
  • Gijo John
  • Sujatha Gopal Sooraparaju
  • Surya Kumari Nujella
  • Kyatham Sowmya
چکیده

Aim The aim of this study is to compare and to evaluate effect of curing light and curing modes on the nanohybrid composite resins with conventional Bis-GMA and novel tricyclodecane (TCD) monomers. Methodology Two nanohybrid composites, IPS empress direct and charisma diamond were used in this study. Light-emitting diode (LED)-curing unit and quartz-tungsten-halogen (QTH)-curing unit which were operated into two different modes: continuous and soft start. Based on the composite resin, curing lights, and mode of curing used, the samples were divided into 8 groups. After polymerization, the samples were stored for 48 h in complete darkness at 37°C and 100% humidity. The Vickers hardness (VK) of the surface was determined with Vickers indenter by the application of 200 g for 15 s. Three VK readings were recorded for each sample surface both on top and bottom surfaces. For all the specimens, the three hardness values for each surface were averaged and reported as a single value. The mean VK and hardness ratio were calculated. The depth of cure was assessed based on the hardness ratio. Results Comparison of mean hardness values and hardness ratios was done using ANOVA with post hoc Tukey's test. Conclusion Both QTH- and LED-curing units had shown the adequate depth of cure. Soft-start-curing mode in both QTH- and LED-curing lights had effectively increased microhardness than the continuous mode of curing. TCD monomer had shown higher hardness values compared with conventional Bis-GMA-containing resin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of three different curing methods on the microleakage of cl V posterior composite restorations

The effect of three different curing methods on the microleakage of cl V posterior composite restorations Dr. N. Mohammadi* - Dr. P. Alizadeh Oskoee* - Dr. S. Savadi Oskoee*- Dr. A . Soleyman zadeh** *- Assistant Professor of Esthetic & Operative Dentistry Dept. - Faculty of Dentistry – Tabriz University of Medical Sciences.*- Dentist. Background and Aim: Light-cured composites have become almo...

متن کامل

Comparison of the Effect of Three LED Light Modes and Conventional QTH Curing Light on Shear Bond Strength of Composite to Dentin

  Objective: Shear bond strength is an important property inherent to the durability of tooth-colored restorative materials namely composite resins. It has been years that halogen light sources have been used for polymerization of composite resins. In recent years Light Emitting Diodes (LED) have been introduced for this purpose. With respect to their longer bulb life, needless of a filter and ...

متن کامل

Effect of composite shade, curing time and mode on temperature rise of silorane and methacrylate- based composite resins

Introduction: The present study was performed to evaluate the effects of light-curing modes and shades of methacrylate and silorane-based composite resins on temperature rise during polymerization of composite resins. Materials &Methods: In this in vitro study, ninety composite samples with two types of composite resin - methacrylate-based and a low-shrinkage silorane-based were prepared, in...

متن کامل

The Knoop hardness of a composite resin polymerized with different curing lights and different modes.

AIM The purpose of this study was to compare the surface hardness of a hybrid composite resin polymerized with different curing lights. METHODS AND MATERIALS Two 3.0 mm thick composite resin discs were polymerized in a prepared natural tooth mold using: (1) a conventional quartz-tungsten halogen light (QTH- Spectrum 800); (2) a high-intensity halogen light, Elipar Trilight (TL)-standard/expon...

متن کامل

The Effect of Standard and Extended Curing Time in Different Distances on Composite’s Degree of Conversion

Introduction: The aim of this study was to in-vestigate the effect of irradiation duration and distance of light tip to prepared samples in two different light curing unites on the degree of conversion of resin composite. Materials and Methods: Conventional halogen and blue Light emitting diode (LED) units were used for polymerization of an Opalis resin com-posite. The conversion measurements w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2018