Test-retest reliability and minimal detectable change scores of twelve functional fitness tests in adults with Down syndrome.

نویسندگان

  • P H Boer
  • S J Moss
چکیده

AIM The purpose of the study was to explore the test-retest reliability and minimal detectable change of selected functional fitness test items in adults with Down syndrome. METHODS Forty-three adults with Down syndrome (24 men and 19 women) aged 18-50 years completed a battery of tests twice in a two-week period. The battery of tests consisted of two balance items, two flexibility items, five muscular strength and endurance items, two aerobic items, and one functional task. All items were considered valid and reliable tests in a general elderly or intellectually disabled population. The test-retest relative reliability for all repeated tests was assessed with intraclass correlation coefficient performing one-way analysis of variance. The test-retest absolute variability was measured by using the standard error of measurement (SEM) to calculate the minimal detectable change at the 90% confidence interval (MDC90). Reliability data was visualised with a Bland-Altman plot. RESULTS All tests showed excellent intraclass correlation coefficients (ICC's>0.9). All SEM values demonstrated acceptable measurement precision (SEM<SD/2). Values for MDC90 are provided for all 12 tests. The analyses indicated that there was no major systematic bias in the plots. The scatter around the Bland-Altman was distributed randomly. CONCLUSION All twelve functional fitness tests demonstrated adequate feasibility and relative and absolute test-retest reliability in adults with Down syndrome in South Africa. Information of this nature will help to monitor performance alterations over time and success of training interventions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke

Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...

متن کامل

Test-retest reliability and minimal detectable change on balance and ambulation tests, the 36-item short-form health survey, and the unified Parkinson disease rating scale in people with parkinsonism.

BACKGROUND AND PURPOSE Distinguishing between a clinically significant change and change due to measurement error can be difficult. The purpose of this study was to determine test-retest reliability and minimal detectable change for the Berg Balance Scale (BBS), forward and backward functional reach, the Romberg Test and the Sharpened Romberg Test (SRT) with eyes open and closed, the Activities...

متن کامل

Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

  Abstract   Background: Postural instability has been identified as a potential precursor of   falls in elderly subjects. Postural stability in quiet stance is commonly assessed with   center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure   (COP) measures in the elderly subjects.   Met...

متن کامل

پایایی آزمون-بازآزمون، روایی سازه و همخوانی درونی نسخه فارسی‌شده آزمون «مقیاس تعادل پیشرفته فولرتون» در سالمندان ایرانی مقیم جامعه

Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal&nbsp;consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community-&nbsp;dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protoco...

متن کامل

Test-retest reliability and minimal detectable change scores for the timed "up & go" test, the six-minute walk test, and gait speed in people with Alzheimer disease.

BACKGROUND With the increasing incidence of Alzheimer disease (AD), determining the validity and reliability of outcome measures for people with this disease is necessary. OBJECTIVE The goals of this study were to assess test-retest reliability of data for the Timed "Up & Go" Test (TUG), the Six-Minute Walk Test (6MWT), and gait speed and to calculate minimal detectable change (MDC) scores fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Research in developmental disabilities

دوره 48  شماره 

صفحات  -

تاریخ انتشار 2016