Comparative study of osteoblastic activity of same implants (Endopore) in the immediate extraction site utilizing single photon emission computerized tomography: peri-implant autogeneous bone grafting with GTR versus no peri-implant bone grafting--experimental study in pig model.

نویسندگان

  • C Ogunsalu
  • C Ezeokoli
  • A Archibald
  • J Watkins
  • C Stoian
  • H Daisley
  • C Legall
  • S Lorde
  • K Jackson
  • D Jaggernauth
  • A Nelson
  • N Mungal
چکیده

The study was designed to exploit the single photon emission computerized tomography (SPECT) to compare osteoblastic activity of two implant systems: an Endopore implant (Beaded implants) placed immediately into an extraction socket in conjunction with peri-implant autogenous grafting supplemented with a guided tissue regeneration (GTR) technique, and an Endopore implant placed immediately into the extraction socket without peri-implant grafting and GTR. Endopore implants of the same size (12 mm x 4.1 mm INT-Hex) were placed in fresh extraction sockets in the canine-tooth region of the pigs jaw. The implant on the right side had peri-implant bone grafting utilizing autogenous bone together with cytoplast resorbable GTR membrane, whilst the implant on the left side received no peri-implant bone grafting. Osteoblastic activity was evaluated 81 days (11 weeks and 4 days) post implantation using the SPECT imaging technique. The SPECT imaging revealed more osteoblastic activity on the side with peri-implant bone grafting as compared with the site without peri-implant bone grafting. The result suggests that peri-implant bone grafting with GTR around the immediate implant showed more osteoblastic activity and thus enhanced osseointegration when compared with the implant without bone grafting and GTR. Bone grafting and GTR should be encouraged as a standard procedure with dental implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone scintigraphy and SPECT in the evaluation of the osseointegrative response to immediate prosthetic loading of endosseous implants: a pilot study.

PURPOSE Several recent medical reports have focused attention on the possible application of skeletal scintigraphy imaging in odontostomatology. The aim of the present report was to assess the influence of immediate prosthetic loading on peri-implant osteoblastic activity through bone scintigraphy. MATERIALS AND METHODS Implants were placed in 2 healthy women. A nuclear medicine investigation...

متن کامل

Adipose- Derived Stem Cells as a Tool for Dental Implant Osseointegration: an Experimental Study in the Dog

The biological interaction between the jaw bones and dental implant is fundamental for the long-term success of dental implant placement. Nevertheless, the insufficient bone volume remains a major clinical problem, especially in case of immediate dental implant. Using a canine model, the present study proves the regenerative potential of adipose- derived stem cells (ADSCs) to repair peri-implan...

متن کامل

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

Clinical and Radiographical Evaluation of Immediate Implant versus Delayed Implant after Socket Preservation of Upper Anterior Teeth

Introduction: After tooth extraction, the alveolar bone remodeled and resorbed. The preservation of ridge resorption following tooth extraction through socket grafting helped to optimize bony fill, thereby maintaining vertical bone height and helped to stabilize the marginal soft tissue at the site. Adequate bone allowed the implant to be placed in the most ideal restorable position in a three ...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The West Indian medical journal

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 2011